A Temperature Stable Inside-Out NMR Sensor

出版社

IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
DOI: 10.1109/TIM.2022.3227991

关键词

Inside-out nuclear magnetic resonance (NMR) sensor; low-gradient fields; low permeability ferrimagnetic material (LPFM); sensitive volume; uniform design (UD)

向作者/读者索取更多资源

This article describes the design and implementation of an inside-out NMR sensor that can maintain stable measuring capability in fluctuating working temperatures. It achieves this by using a ring made of a low permeability ferrimagnetic material (LPFM) to decrease inhomogeneity, adjust the static gradient, and enhance the strength of the radio frequency (RF) field.
Inside-out nuclear magnetic resonance (NMR) sensors provide a practical way to conduct porous medium materials measurement. However, they usually suffer from poor temperature stability, thus limit their applications outside the temperature controlled environment. This article describes the design and implement of an inside-out NMR sensor useful to overcome the sensitive volume fluctuation caused by temperature variation. The use of a ring made of a low permeability ferrimagnetic material (LPFM) simultaneously decrease the inhomogeneity along the axial direction, adjust the static gradient G(0) and enhance the strength of radio frequency (RF) field B-1. In this way, the sensor can maintain the shape and position of the sensitive volume to achieve stable measuring capability under fluctuating working temperature. The uniform design (UD) approach is applied to obtain the optimal structure of magnet and RF coil. The performance of the LPFM-based sensor in terms of field distribution, coil efficiency, and sensitivity map is evaluated and compared with the structure without the ring based on finite element method (FEM) simulation. When the working temperature ranging from 10 degrees C to 50 degrees C, the sensitive volume of the LPFM-based sensor maintains the shape of a toroidal crescent with an axial extension of 10-14 mm and a radial extension of 3-4 mm. Moreover, the position of the sensitive volume is stably located in similar to 5 mm from the magnet surface without being affected by working temperature. Then, we built a prototype sensor to conduct the T-2 relaxation experiments on CuSO4 center dot H2O samples. The results demonstrate a stable NMR signal strength over a working temperature range of 10 degrees C-50 degrees C. The proposed NMR sensor construction can be applied to borehole logging and soil moisture measurements.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据