4.6 Article Proceedings Paper

Loop Optimization Noise-Reduced LSTM Based Classifier for PD Detection

期刊

IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS
卷 59, 期 1, 页码 392-402

出版社

IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
DOI: 10.1109/TIA.2022.3215642

关键词

Feature extraction; Voltage measurement; Optimization; Noise reduction; Neural networks; Noise measurement; Power measurement; Detection solution; feature extraction; loop optimization; neural network applications; noise reduction; partial discharges; signal processing

向作者/读者索取更多资源

Partial discharge (PD) is a major factor contributing to power failures, and its timely and accurate detection is crucial for maintaining power system stability. This paper proposes a loop optimization noise-reduced LSTM-based classifier for PD detection, which effectively combines noise reduction, feature extraction, and the LSTM neural network. The proposed method outperforms other techniques in the literature, achieving an accuracy of 95.4% in detecting PD in medium voltage overhead power lines.
Partial discharge (PD) is an important inducement of power failures such as insulation degradation. Effective, timely, and economical detection of the PD is the basis for maintaining power system stability. This paper proposes a loop optimization noise-reduced LSTM based classifier for PD detection of large-scale data disturbed with measurement noise. It establishes the loop optimization to greatly coordinate the data processing and data-driven based machine learning algorithm. The noise reduction, feature extraction, and the long short-term memory (LSTM) neural network are combined as a whole with internal linkages. The proposed method combines these three necessary steps to achieve a better solution for the PD detection, while other methods are in general single ones, and not dedicated designed for the solution. The combination of the different methods has combined advantages and can overcome each individual's drawback. This comprehensive solution is verified using large real trial data measured from medium voltage (MV) overhead power lines. It exhibits superior performance and great practicality for PD detection of MV overhead power lines with an accuracy of 95.4%. It outperforms other techniques in the literature based on the experimental results. This paper also summarizes the loop optimization rules for PD detection solutions based on extensive experiments and analysis. The loop optimization rules are competent for the optimization of wider engineering applications of PD detection.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据