A trielectrode capacitance sensor (TECS) is designed for water cut measurement in horizontal oil-water flow, with static, dynamic experiments and field testing validating its effectiveness in different conditions.
From the actual development and testing re quirements of horizontal wells in domestic oilfields, according to the problems that the common sensors have relatively low resolution during the water cut measurement for the oil-water flow in the horizontal wells with medium and low production, a trielectrode capacitance sensor (TECS) is designed and a water cut measurement system based on TECS is developed for different conditions of horizontal oil-water flow. Specifically, the electrostatic field distribution of the annular measurement region is investigated under different conditions of horizontal stratified flow. Then, its equivalent capacitance on the electrodes is analyzed. Based on the simulated results, the effects of structural parameters on sensitivity distribution are analyzed, including the electrode length, the radius of the flow channel, and the thickness of the insulation, determining its optimal structure. Moreover, the static and dynamic experiments, as well as the field testing, validate the designed TECS, indicating that the TECS enables measuring the water cut of horizontal oil-water flow, especially under low flow rate and oil-water stratified conditions. The developed TECS could realize the water cut measurement with a wide flow rate range (3-60 m(3)/d) and the full water cut range (0%-100%) for the horizontal oil-water flow.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.8
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据