This work presents an experimental assessment of the influence of cryogenic cooling on a conventional induction motor. The study finds that when submerged in liquid nitrogen, the motor's performance parameters vary and it achieves higher efficiency and torque.
In this work, an experimental assessment of the influence of cryogenic cooling in a conventional induction motor is presented. The performance of a fractional kilowatt induction motor is evaluated when submerged in liquid nitrogen. Using the single-phase equivalent electric circuit, the influence of the temperature and skin-effect is analyzed in the variation of the machine's parameters, under ambient and cryogenic conditions. Also, the variation of the iron core and mechanical losses are evaluated. An analytical methodology is proposed to estimate the change of motor performance under cryogenic conditions. For the analyzed induction motor, measurements are performed to verify the predicted machine performance. The experimental tests in cryogenic conditions show the possibility of achieving higher efficiency levels with more than double the nominal torque. Also, due to the cryogenic environment, there was no thermal constraint in the operation of the induction motor.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据