4.7 Article

Remote Monitoring of Skin Temperature Through a Wristband Employing a Printed VO2 Sensor

期刊

IEEE SENSORS JOURNAL
卷 23, 期 1, 页码 169-180

出版社

IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
DOI: 10.1109/JSEN.2022.3223947

关键词

Temperature sensors; Sensors; Skin; Temperature measurement; Sensitivity; Fabrication; Antennas; Flexible antennas; flexible temperature sensors; on-body antennas; on-body worn sensors; printed sensors; vanadium dioxide (VO2)-based sensor

向作者/读者索取更多资源

The demand for highly sensitive, environmentally stable, mechanically flexible, and low-cost temperature sensors for on-body measurements has been increasing due to the popularity of personal healthcare-Internet-of-Things (H-IoT) devices. Printed Electronics (PE) is an ideal platform for such sensors as it allows for the production of flexible devices using simple and rapid methods at a relatively low cost. In this article, a custom-made tungsten-doped vanadium dioxide ink-based screen-printed temperature sensor with high resistance temperature coefficient (TCR) and environmental stability is reported. A fluoropolymer-based passivation layer is added to protect the sensor from the environment, and the sensor is integrated with a custom Bluetooth Low Energy (BLE) wireless readout in the form of a wristband.
The need for highly sensitive, environmentally stable, mechanically flexible, and low-cost temperature sensors for on-body measurements has been increasing with the wide adoption of personal healthcare-Internet-of-Things (H-IoT) devices. Printed electronics (PE) is a good platform for such sensors because it enables the realization of flexible devices through simple and rapid methods at a relatively low cost. However, previously reported printed temperature sensors suffer frompoor sensitivity and/or environmental instability. In this article, we report a custom tungsten (W)-doped vanadium dioxide (VO2) ink-based screen-printed temperature sensor having the highest temperature coefficient of resistance (TCR) of 2.78%.center dot C-1 with a resolution of 0.1 degrees C between 30 degrees C and 40 degrees C. To protect it from environmental effects, a fluoropolymer-basedpassivation layer is added for accurate temperature readings even in 90% relative humidity. The sensor is printed on a flexible substrate and shows minimal deterioration in performance over 1000 bending cycles. For wearability and remote monitoring, the sensor is integrated with a custom Bluetooth low energy (BLE) wireless readout in the form of wristband. The BLE readout comprises an ultrathin and flexible patch antenna optimized for both BLE bandwidth (BW) and human wearability. It demonstrates a minimal specific absorption rate (SAR) value of only 0.068 W/kg, making it safe to wear. Despite the antenna's thin structure (0.004 lambda),it has a gain of 1.65 dBi, enabling an excellent communication range. The proposed wristband is tested on ten volunteers and under daily activities, which shows promising results with a maximum error of 0.16 degrees C with reference to those of a commercial thermometer.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据