Parametric and Noise Effects on Magnetic Sensing System for Monitoring Human-Joint Motion of Lower Extremity in Sagittal Plane

期刊

IEEE SENSORS JOURNAL
卷 23, 期 5, 页码 4729-4739

出版社

IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
DOI: 10.1109/JSEN.2023.3237130

关键词

Sensors; Magnetic sensors; Motion measurement; Legged locomotion; Noise measurement; Robot sensing systems; Magnetic field measurement; Joint kinematics; joint motion tracking; magnetic sensing; wearable sensor

向作者/读者索取更多资源

This article introduces a 3-DOF magnetic sensor, called a pantographic exoskeleton (PGE) sensor, which can monitor the internal human-joint motion in real time. The PGE sensor, equipped with two sets of embedded magnetic sensors and a permanent magnet, can independently measure the translations and joint angle. Two sensor estimation methods, model-based and artificial neural network (ANN), are experimentally analyzed. The PGE sensors are evaluated for sit-to-stand exercises, and the results are compared with a commercial VICON motion capture system and a 4-DOF platform manipulated to follow a specified internal motion trajectory of an ankle joint.
This article presents a three-degree-of-freedom (3-DOF) magnetic sensor, referred to here as a pantographic exoskeleton (PGE) sensor, for monitoring in real time the internal human-joint motion in the sagittal plane. With two sets of embedded magnetic sensors and a permanent magnet, the PGE wearable on a healthy leg or lower extremity exoskeleton (LEE) independently measures the 2-DOF translations and the joint angle. Two sensor estimation methods, which are the model-based and the artificial neural network (ANN), are experimentally analyzed in the presence of measurement noise. As an illustration, the PGE sensors are evaluated for sit-to-stand (STS) exercises, where the real-time measurements are verified by comparing with the joint angles determined by a commercial VICON motion capture system, and the translational deviations measured on a 4-DOF platform manipulated to follow a specified internal motion trajectory of an ankle joint during STS. With the ANNs appropriately trained to account for measurement noise, the PGE sensors can track the joint angles while measuring the internal motions of both legs with or without the LEE demonstrating that the PGE sensor has the potential to serve as an indicator of stroke rehabilitation where patients lack force perception and suffer an increased risk of falls due to the weak affected leg.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据