4.7 Article

Nano-Functionalized Electrochemical Sensors by Aerosol Jet Printing

期刊

IEEE SENSORS JOURNAL
卷 22, 期 22, 页码 21498-21507

出版社

IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
DOI: 10.1109/JSEN.2022.3213349

关键词

Aerosol jet printing (AJP); carbon nanotubes (CNTs); electrochemical sensors; graphene; hydrogen peroxide; nanostructures; printed sensors

向作者/读者索取更多资源

In recent years, the quantification of hydrogen peroxide has attracted increasing attention in various fields. Electrochemical transducers have gained particular interest due to their ease of fabrication, convenient integration with microfluidics and electronics, and cost-effectiveness. This study utilizes the novel technique of Aerosol jet printing to fabricate fully printed nanostructured electrochemical sensors for hydrogen peroxide detection. The performances of carbon nanotubes (CNTs) and graphene as printable nanostructures are explored and discussed. Both materials demonstrate comparable limit of detections (LODs) and sensitivity, with CNTs performing better in terms of sensitivity and graphene having a better resistance against noise.
In the latest years, hydrogen peroxide quantification gained a growing interest in many fields both in industry and in the clinical environment. Among the different available methods, electrochemical transducers are of particular interest thanks to their ease of fabrication, convenient integration with microfluidics and electronics and their time and cost-effectiveness. Despite these advantages, electrochemical transducers are affected by many metrological issues. In this work, the novel technique of Aerosol jet printing (AJP) is exploited to fabricate fully printed nanostructured electrochemical sensors for hydrogen peroxide detection. Two different carbon-based printable nanostructures, carbon nanotubes (CNTs) and graphene, are employed to conveniently modify with the same technique electrodes' surfaces. The performances of the proposed design, production process and the different functionalization are explored and discussed. After a preliminary evaluation of the electrochemical characteristics of the printed devices, tests in hydrogen peroxide are carried on. Both materials present a limit of detections (LODs) and sensitivity comparable with the ones obtained in the literature, even though CNT better performs than graphene in terms of sensitivity (20 versus 2.8 mu mM(-2)). The latter presents however a signal-to-noise ratio (SNR) of 51.2 dB that outperforms the one of CNT (26.5 dB) and thus it has a better resistance against noise. Overall, both the evaluated nanostructures appear suitable to improve the metrological characteristics of printed electrochemical sensors and ease their spreading as environmental control devices, and diagnostic tools and assess quality in the industrial environment.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据