4.7 Article

Remote Health Monitoring System for the Estimation of Blood Pressure, Heart Rate, and Blood Oxygen Saturation Level

期刊

IEEE SENSORS JOURNAL
卷 23, 期 5, 页码 5401-5411

出版社

IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
DOI: 10.1109/JSEN.2023.3235977

关键词

Sensors; Monitoring; Temperature measurement; Heart rate; Biomedical monitoring; Temperature sensors; Blood pressure; Blood pressure (BP) monitoring; heart rate (HR); medical devices; oxygen saturation level; remote monitoring; wearable body ring sensor

向作者/读者索取更多资源

This article presents the design and implementation of an IoT-based remote health monitoring system for estimating BP, HR, and SpO2 levels. A sensor is used to remotely monitor these parameters, and the collected data is stored on a remote platform called ThinkSpeak. The system includes a display for viewing health readings locally.
This article presents the design and implementation of an Internet of Things (IoT)-based remote health monitoring system for the estimation of blood pressure (BP), heart rate (HR), and blood oxygen saturation levels (SpO2). Our designed sensor can remotely monitor BP, HR, and SpO2. Our device collects, evaluates, predicts, and reads health data and then stores it on a remote platform named ThinkSpeak, which forms an IoT platform, with a 0.91 organic light-emitting diodes (OLEDs) screen display for viewing numerical health readings locally. We used a biomedical sensor device with an embedded signal condition unit, and a single photoplethysmography (PPG) signal was employed to derive and measure the PPG signal. A computer-based algorithm was generated, which factored in selected beneficial parameters measured from a single bio-inspired PPG signal. The measured PPG signal was used to estimate the individual user's BP (both systolic and diastolic values), HR, and SpO2. An automatic multiscale-based peak (AMBP) detection algorithm was developed to obtain the maximum peak of the PPG signal. Furthermore, the developed sensor was benchmarked against two standard commercially available measurement devices: a Contec ambulatory BP sensor and a Braun pulse oximeter monitor. Our developed sensor is worn as a ring sensor and is interfaced with an Arduino 1010 WIFI MKR for remote health monitoring. Our estimated BP, HR, and SpO2 values were remotely monitored and a graphical representation was constructed.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据