4.6 Article

High Resolution 4H-SiC p-i-n Radiation Detectors With Low-Voltage Operation

相关参考文献

注意:仅列出部分参考文献,下载原文获取全部文献信息。
Article Engineering, Electrical & Electronic

Radiation tolerance analysis of 4H-SiC PIN diode detectors for neutron irradiation

R. L. Gao et al.

Summary: This study investigates the characteristics of 4H-SiC PIN diode detectors under harsh neutron irradiation environments. The results show that the detectors exhibit excellent neutron radiation tolerance and maintain relatively stable performance even after irradiation.

SENSORS AND ACTUATORS A-PHYSICAL (2022)

Article Engineering, Electrical & Electronic

Development of p-i-n radiation detectors based on semi-insulating 4H-SiC substrate via dual-face ion implantation

Qunsi Yang et al.

Summary: In this study, p-i-n diodes with thick depletion layers were fabricated on semi-insulating 4H-SiC substrate using a dual-face ion implantation technique. The investigation revealed that Poole-Frenkel emission is responsible for the reverse leakage current transport of the p-i-n diode at elevated temperatures. Detection tests of alpha-particles showed weak p-type conduction of the SI 4H-SiC substrate after high temperature post-implantation annealing, with the energy resolution degrading at higher biases.

SOLID-STATE ELECTRONICS (2022)

Article Engineering, Electrical & Electronic

Low-Voltage p-i-n GaN-Based Alpha-Particle Detector With High Energy Resolution

Qianyu Hou et al.

Summary: In this study, a low-voltage p-i-n GaN-based alpha-particle detector with excellent energy resolution was fabricated. Superior performances were achieved by artificially enlarging the path of alpha particles in the depletion region and utilizing high crystal quality epitaxial film grown on a single-crystal GaN substrate. The results are expected to advance the research of radiation-hardened GaN-based detectors.

IEEE ELECTRON DEVICE LETTERS (2021)

Article Instruments & Instrumentation

Direct metal contacts printing on 4H-SiC for alpha detectors and inhomogeneous Schottky barriers

Neil R. Taylor et al.

Summary: Electrical characterization of 4H-SiC Schottky diodes with Aerosol-Jet printed metal contacts showed many devices exhibiting nonideal behavior and inferior performance, yet still achieving good α radiation detection capability.

NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT (2021)

Article Materials Science, Multidisciplinary

Improved performance of SiC radiation detectors due to optimized ohmic contact electrode by graphene insertion

Yuping Jia et al.

Summary: Graphene inserted between metal ohmic electrode and SiC enhances the formation of carbon compounds to reduce contact resistance. The adjustable Fermi level of graphene enlarges the interface barrier to accelerate the separation of electron-hole pairs.

DIAMOND AND RELATED MATERIALS (2021)

Article Engineering, Electrical & Electronic

Systematic Analysis of Reliability of Large-Area 4H-SiC Charged Particle Detector Under Harsh He Ion Irradiation

Run-Long Gao et al.

Summary: The research shows that the 4H-SiC detectors have resistivity 10(4) times greater than silicon detectors when exposed to He ion irradiation, demonstrating good stability and performance. With increasing irradiation fluence, the CCE and energy resolution of the detectors decreases, but they still maintain low dark current and high linearity of energy response.

IEEE TRANSACTIONS ON NUCLEAR SCIENCE (2021)

Article Physics, Applied

High-resolution radiation detection using Ni/SiO2/n-4H-SiC vertical metal-oxide-semiconductor capacitor

Sandeep K. Chaudhuri et al.

Summary: This article demonstrates the radiation detection performance of vertical metal-oxide-semiconductor (MOS) capacitors fabricated on n-4H-SiC epitaxial layers, achieving the highest energy resolution reported. The MOS detectors showed excellent energy resolution for alpha particles and lower enhancement in electronic noise compared to Schottky barrier detectors. Published under an exclusive license by AIP Publishing.

JOURNAL OF APPLIED PHYSICS (2021)

Article Physics, Applied

Defect characterization and charge transport measurements in high-resolution Ni/n-4H-SiC Schottky barrier radiation detectors fabricated on 250μm epitaxial layers

Joshua W. Kleppinger et al.

Summary: This study reports the fabrication and characterization of high-resolution Schottky barrier radiation detectors on 250 μm thick n-type 4H-SiC epitaxial layers, with promising performance in terms of effective doping concentration, leakage current, energy resolution, and charge collection efficiency. The results show that the detectors display excellent performance due to ultralow concentrations of lifetime limiting defects.

JOURNAL OF APPLIED PHYSICS (2021)

Article Engineering, Electrical & Electronic

Effect of Very High-Fluence Proton Radiation on 6H-SiC Photoconductive Proton Detectors

Qing Liu et al.

IEEE ELECTRON DEVICE LETTERS (2019)

Article Instruments & Instrumentation

High resolution alpha particle detectors based on 4H-SiC epitaxial layer

B. Zat'ko et al.

JOURNAL OF INSTRUMENTATION (2015)

Article Instruments & Instrumentation

Schottky barrier detectors on 4H-SiC n-type epitaxial layer for alpha particles

S. K. Chaudhuri et al.

NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT (2013)

Article Instruments & Instrumentation

High resolution alpha particle detection using 4H-SiC epitaxial layers: Fabrication, characterization, and noise analysis

Sandeep K. Chaudhuri et al.

NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT (2013)

Proceedings Paper Engineering, Electrical & Electronic

Ultra Low Noise Epitaxial 4H-SiC X-Ray Detectors

G. Bertuccio et al.

SILICON CARBIDE AND RELATED MATERIALS 2008 (2009)

Article Engineering, Electrical & Electronic

High-resolution alpha-particle spectrometry using 4H silicon carbide semiconductor detectors

Frank H. Ruddy et al.

IEEE TRANSACTIONS ON NUCLEAR SCIENCE (2006)

Article Engineering, Electrical & Electronic

1/f noise in Langmuir-Blodgett films on silicon

S Malik et al.

SEMICONDUCTOR SCIENCE AND TECHNOLOGY (2005)

Article Instruments & Instrumentation

Silicon carbide for high resolution X-ray detectors operating up to 100°C

G Bertuccio et al.

NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT (2004)

Article Engineering, Electrical & Electronic

Minimum ionizing and alpha particles detectors based on epitaxial semiconductor silicon carbide

F Nava et al.

IEEE TRANSACTIONS ON NUCLEAR SCIENCE (2004)

Article Engineering, Electrical & Electronic

A novel multicell silicon drift detector module for X-ray spectroscopy and imaging applications

K Hansen et al.

IEEE TRANSACTIONS ON NUCLEAR SCIENCE (2000)