4.5 Article

Cryoballoon Pulmonary Vein Isolation as First-Line Treatment for Typical Atrial Flutter

期刊

HEART
卷 109, 期 5, 页码 364-371

出版社

BMJ PUBLISHING GROUP
DOI: 10.1136/heartjnl-2022-321729

关键词

Atrial Fibrillation; Arrhythmias; Cardiac; Atrial Flutter; Ablation Techniques; Catheter Ablation

向作者/读者索取更多资源

The study compared cryoballoon pulmonary vein isolation (PVI) with standard radiofrequency cavotricuspid isthmus (CTI) ablation for the first-line treatment of typical atrial flutter (AFL). The results showed that cryoballoon PVI was equally effective as CTI ablation in preventing the recurrence of atrial arrhythmia and better at preventing new-onset atrial fibrillation (AF).
Objective We aimed to compare cryoballoon pulmonary vein isolation (PVI) with standard radiofrequency cavotricuspid isthmus (CTI) ablation as first-line treatment for typical atrial flutter (AFL).Methods Cryoballoon Pulmonary Vein Isolation as First-Line Treatment for Typical Atrial Flutter was an international, multicentre, open with blinded assessment trial. Patients with CTI-dependent AFL and no documented atrial fibrillation (AF) were randomised to either cryoballoon PVI alone or radiofrequency CTI ablation. Primary efficacy outcome was time to first recurrence of sustained (> 30 s) symptomatic atrial arrhythmia (AF/AFL/atrial tachycardia) at 12 months as assessed by continuous monitoring with an implantable loop recorder. Primary safety outcome was a composite of death, stroke, tamponade requiring drainage, atrio-oesophageal fistula, pacemaker implantation, serious vascular complications or persistent phrenic nerve palsy.Results Trial recruitment was halted at 113 of the target 130 patients because of the SARS-CoV-2 pandemic (PVI, n=59; CTI ablation, n=54). Median age was 66 (IQR 61-71) years, with 98 (86.7%) men. At 12 months, the primary outcome occurred in 11 (18.6%) patients in the PVI group and 9 (16.7%) patients in the CTI group. There was no significant difference in the primary efficacy outcome between the groups (HR 1.11, 95% CI 0.46 to 2.67). AFL recurred in six (10.2%) patients in the PVI arm and one (1.9%) patient in the CTI arm (p=0.116). Time to occurrence of AF of & GE;2 min was significantly reduced with cryoballoon PVI (HR 0.46, 95% CI 0.25 to 0.85). The composite safety outcome occurred in four patients in the PVI arm and three patients in the CTI arm (p=1.000).Conclusion Cryoballoon PVI as first-line treatment for AFL is equally effective compared with standard CTI ablation for preventing recurrence of atrial arrhythmia and better at preventing new-onset AF.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据