期刊
FUSION ENGINEERING AND DESIGN
卷 185, 期 -, 页码 -出版社
ELSEVIER SCIENCE SA
DOI: 10.1016/j.fusengdes.2022.113324
关键词
Discrete Rogowki coil measurement; Plasma current; Toroidal eddy current; In -vessel components; Current quench time; Korea Superconducting Tokamak Advanced; Research tokamak
资金
- Korea Institute of Fusion Energy - Korea Ministry of Science and ICT (MSIT) [EN2201-12]
- National Research Council of Science & Technology (NST), Republic of Korea [EN2201] Funding Source: Korea Institute of Science & Technology Information (KISTI), National Science & Technology Information Service (NTIS)
This paper discusses the measurement of plasma current in the vacuum vessel of the KSTAR tokamak. By using local magnetic field measurements and subtracting the eddy current induced by the tokamak vessel, a more accurate evaluation of the plasma current can be obtained.
The plasma current was earlier measured by a Rogowski coil on the wall inside the vacuum vessel of the KSTAR tokamak. After installing in-vessel components, this measurement included toroidal eddy currents induced on the in-vessel components between plasma boundary and the wall in the transient phases. The plasma current is now evaluated by using the sum of local poloidal magnetic field measurements, as a discrete Rogowki coil measurement, at the plasma facing components along a poloidal circumference that does not encompass the eddy currents. These two measurements agree to within a few percent in the flat-top phase of the discharge. The current quench time previously overestimated by the Rogowski coil measurement can be now evaluated from the linear fit on the wave-form of the plasma current excluding the eddy current during the disruption, so it is more accurately estimated as 2.7 +/- 1.0 ms for the plasma current of 0.3-1.1 MA. In addition, an estimate of the eddy currents is obtained by subtracting the discrete Rogowski coil measurement from the Rogowski coil measurement in the transient phases, and its magnitude is validated by comparing with the toroidal current directly measured at the gap resistors connecting two adjacent passive stabilizers.
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。
推荐