This study evaluated the health effects of combined or separate exposure to hazardous factors in plasma technology occupational environment on animal models. The results showed that exposure to noise or its combination with chemical factors led to non-specific changes in the CNS, especially in the case of joint exposure.
Objectives: To evaluate on animal models the health effects of the combined or separate exposure to main chemical and physical hazards of plasma-based material processing technology environment.Materials and methods: Male Wistar rats were exposed to actual levels of hazardous factors in plasma technology occupational environment: i.e., ozone and nitrogen oxides (O3 and NOx) in respective concentrations of 0.5 mg/ m3 and 1.0 mg/m3 and high-frequency (1000-1600 Hz) of 112 dB intensity noise for 3 h/day, 5 days/week for 12 weeks, with a recovery period of 1 month.Results: Exposure to noise or its combination with chemical factors (ozone, nitrogen oxides) causes non-specific CNS changes testifying for significant excitation dominance, especially in the case of joint exposure. Histological examination of rats' brain in experimental revealed a pronounced increase in blood filling of small vessels on the tenth day of the experiment, with subsequent intensification of vascular alterations and eventually to cerebral edema. The exposure to noise significantly reduced total thymus, bone marrow and spleen cell numbers and these was also more pronounced under the joint impact of noise and toxic gases. Thymus, but not bone marrow or spleen, mitotic activity was as well reduced under the same modes of exposure. Cytological investigation of film preparations of subcutaneous connective tissue revealed that joint exposure led to microcirculatory disor-ders, increased number of dark mast cells and reduced degranulation processes indicative of increased autor-egulatory processes effective at microvasculature level.Conclusions: High-frequency and intensity noise is main stressor factor that has negative impact on CNS and immune system, morphology and functioning of hematopoietic organs (spleen, bone marrow, thymus) and connective tissue. Its negative impact is significantly potentiated by concurrent exposure to ozone and nitrogen oxide, while exposure only to these toxic gases has no significant effect on the above targets.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据