4.7 Article

Seismic behavior of novel GFRP bar reinforced concrete beam-column joints internally reinforced with an FRP tube

期刊

ENGINEERING STRUCTURES
卷 273, 期 -, 页码 -

出版社

ELSEVIER SCI LTD
DOI: 10.1016/j.engstruct.2022.115100

关键词

Fiber-reinforced polymer (FRP) reinforcement; Beam-column joints; FRP tube; Confinement; Seismic performance; Energy dissipation

资金

  1. National Natural Science Foundationof China
  2. Hong Kong Research Grants Council
  3. Natural Science Foundation of Guangdong Province
  4. [51908137]
  5. [52008116]
  6. [T22-502/18-R]
  7. [2019A1515011637]
  8. [2021B1515020029]

向作者/读者索取更多资源

This study aims to develop a novel form of FRP-RC beam-column joints with superior energy dissipation capacity by incorporating an internal FRP tube in the joint zone. Experimental results demonstrated that the FRP tube, especially the one with a fiber angle of +/- 45 degrees, can enhance the energy dissipation capacity of FRP-RC beam-column joints.
Due to many advantages, fiber-reinforced polymer (FRP) bars have been considered as a promising alternative to steel bars in reinforced concrete (RC) structures. The use of FRP bars in beam-column joints has been reported in the literature. However, it has been found that the energy dissipation capacity of an FRP-RC beam-column joint is dramatically lower than that of the corresponding steel-RC joint. The present study attempts to develop a novel form of FRP-RC beam-column joints with superior energy dissipation capacity. The proposed joints incorporate an internal FRP tube in the joint zone, which provides confinement to the inner concrete and shear resistance of the joint. Compared with existing reinforcement techniques using stiffeners or internal diaphragms, the proposed use of an internal FRP tube is much easier to be implemented. To demonstrate the advantages of the proposed FRP-RC beam-column joints, an experimental program consisting of 6 FRP-RC beam-column joint specimens was carried out. The effects of fiber type, thickness, and fiber orientation of the FRP tube in the joint zone were investigated. The test results in terms of failure modes, hysteretic behaviors, and energy dissipation capacities of the test specimens were discussed in detail. The test results demonstrated the efficiency of the FRP tube, espe-cially the one with a fiber angle of +/- 45 degrees, in enhancing the energy dissipation capacity of FRP-RC beam-column joints.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据