4.7 Article

Axial compressive behaviors of engineered cementitious composites-encased concrete filled steel tube columns after fire exposure

期刊

ENGINEERING STRUCTURES
卷 273, 期 -, 页码 -

出版社

ELSEVIER SCI LTD
DOI: 10.1016/j.engstruct.2022.115127

关键词

Engineered cementitious composite; Concrete filled steel tubes; Fire exposure; Compressive load; Numerical model

资金

  1. Natural Science Foundation of China [51908117]
  2. Fundamental Research Funds for the Central Universities [2242022R10133, 2242022k30031, 2242022k3003]

向作者/读者索取更多资源

This paper investigates the fire performance of ECC-encased CFST columns and finds that ECC provides better fire protection than conventional concrete. The ECC-encased CFST columns also exhibit improved strength and ductility after fire exposure.
Engineered cementitious composite (ECC)-encased concrete filled steel tube (CFST) column, which is composed of outer steel reinforced ECC and inner CFST components, has broad application prospects in high-rise buildings due to its higher strength and ductility than the concrete-encased CFST column counterpart. This paper in-vestigates the fire performance of ECC-encased CFST columns under and after fire exposures. Totally thirteen ECC-encased CFST columns and two concrete-encased CFST columns were prepared and tested considering different parameters, i.e., heating-up time, stirrup spacing and fire sides. It was found that the outer ECC component provides better fire protection to the inner CFST than the conventional concrete. Besides, the axial compressive strength and ductility of the ECC-encased CFST column were 32.2 % and 10.3 % higher than those of concrete-encased CFST columns after fire exposure. A finite element (FE) model and design equations were also proposed and verified by the experimental results, which could be applied to simulate and predict the compressive behavior of ECC-encased CFST columns after fire exposure.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据