4.7 Article

Constitutive model of lightweight aggregate concrete confined by circular steel tube

期刊

ENGINEERING STRUCTURES
卷 276, 期 -, 页码 -

出版社

ELSEVIER SCI LTD
DOI: 10.1016/j.engstruct.2022.115355

关键词

Constitutive model; Lightweight aggregate concrete (LAC); Ceramsite; Equivalent lateral confining stress; Compressive stress

向作者/读者索取更多资源

In this study, monotonic axial loading tests were conducted on steel tube confined lightweight aggregate concrete (STCLAC) stub columns to investigate their constitutive model. The effects of diameter-to-thickness (D/t) ratio and steel grade were considered. The results showed bulging outward of steel tubes without local buckling during loading. It is recommended that the D/t ratio for STCLAC columns should be greater than 19.0. The study proposed calculation formulas for the compressive stress and corresponding strain of confined LAC based on test results, and a constitutive model capable of predicting the stress-strain relationship of LAC constrained by a circular steel tube.
To study the constitutive model of lightweight aggregate concrete (LAC) constrained by the circular steel tube, the monotonic axial loading test was carried out on steel tube confined LAC (STCLAC) stub columns, considering the effects of the diameter-to-thickness (D/t) ratio (30.4, 19 and 12.7) and steel grade (Q235 and Q355). The test results showed that the steel tubes of STCLAC columns were bulging outward as a whole without local buckling during the loading process. The D/t ratio for the STCLAC column is recommended that be greater than 19.0. Due to friction stress accumulating at the interface between the steel tube and the LAC core, the steel tube is subjected to longitudinal stress. When the confinement factor (xi) is less than 2.313, the transverse stress of the steel tube reached its yield strength before the peak load, otherwise it reached the proportional stress without yielding. Using the average transverse stresses along the height of the steel tube, this study calculated the equivalent lateral confining stress of the STCLAC column. The calculation formulas of the compressive stress and corre-sponding strain of confined LAC were proposed based on the test results. And the constitutive model was also proposed, which is more capable of predicting the stress-strain relationship of the constrained LAC by a circular steel tube.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据