4.7 Article

Demonstrating non-isothermal vacuum membrane air dehumidification for efficient next-generation air conditioning

期刊

ENERGY CONVERSION AND MANAGEMENT
卷 276, 期 -, 页码 -

出版社

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.enconman.2022.116491

关键词

Membrane; Dehumidification; Non-isothermal; Efficiency; Air conditioning

向作者/读者索取更多资源

Vacuum membrane air dehumidification is an efficient technique, and this study evaluates the performance of the Active Membrane Energy Exchanger (AMX) concept compared to isothermal membrane dehumidification. The study finds that using dense membranes at cooler temperatures increases water vapor permeance by up to 40%, and the prototype system shows up to a 6% increase in humidity removal when the air is cooled simultaneously. Additionally, the integration of heat exchange tubes in the membrane module leads to a 4-8% increase in humidity removal.
Vacuum membrane air dehumidification has gained significant interest in recent years as a highly efficient means of air dehumidification. Prior theoretical modeling work by the authors introduced the Active Membrane Energy Exchanger (AMX) concept, which combines active heat exchange and vacuum membrane dehumidification into one non-isothermal system, and found that it could outperform other air conditioning technologies under many conditions. However, no experimental literature exists on combining active heat exchangers and vacuum membrane dehumidification. The goal of the present study is to evaluate the dehumidification (mass transfer) performance of the AMX concept relative to isothermal membrane dehumidification through three main methodologies: (1) membrane material-level characterization, (2) experimental prototype development and testing, and (3) computational fluid dynamics (CFD) simulations. The dense membranes used in this work showed up to a 40% increase in water vapor permeance at cooler temperatures, and the prototype system showed up to a 6% increase in humidity removal when the air was simultaneously cooled. Furthermore, the membrane module-integrated heat exchange tubes provided additional mixing and turbulence, leading to a 4-8% increase in humidity removal. The upper limit coefficient of performance was equal to approximately 2.2, necessitating advanced system designs to improve efficiency. This study is the first to highlight that combining the cooling and vacuum dehumidification processes can improve dehumidification performance.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据