Economic and Environmental Analysis of Incorporating Geothermal District Heating System Combined with Radiant Floor Heating for Building Heat Supply in Sarein, Iran Using Building Information Modeling (BIM)

期刊

ENERGIES
卷 15, 期 23, 页码 -

出版社

MDPI
DOI: 10.3390/en15238914

关键词

district heating system; radiant floor heating; EnergyPlus; natural gas; municipal solid waste; CO2 mitigation

向作者/读者索取更多资源

This paper aims to design a 100% renewable district heating system integrated with radiant floor heating for residential buildings in Sarein, Iran. A novel approach combining geothermal energy and Municipal Solid Waste (MSW) is proposed to achieve renewable energy. Findings show that the renewable district heating system can reduce energy consumption and greenhouse gas emissions, and generate economic benefits.
Despite the considerable breakthrough in district heating systems (DHS) globally, there is not yet any policy on developing this technology in Iran. This country has a high range of energy demand, while renewable energies play a minor role in its energy supply chain. Furthermore, the world is going through a transition towards renewable resources, which currently consist of only 10% of the total energy mix. As the first contribution in this area, this paper aims to design a 100% renewable DHS integrated with radiant floor heating for a group of residential buildings in Sarein, Iran. Moreover, the literature proposes a novel approach for combining geothermal energy and Municipal Solid Waste (MSW) to achieve a 100% renewable energy system. Building Information Modeling (BIM) is used for thermal analysis by 3D designing the buildings in SketchUp and OpenStudio and simulating the heat load in EnergyPlus. Three scenarios are presented to better compare the DHS with the decentralized heating system regarding fuel consumption, as well as environmental and economic aspects. The town's existing heating system that consumes natural gas for both space heating and hot water demand is referred to as the IHS-G scenario. The DHS-G scenario represents an 87% renewable DHS system, working with natural gas and geothermal energy, while the DHS-MSW scenario is a 100% renewable system, consuming both geothermal energy and Municipal Solid Waste (MSW). Finally, findings suggest that DHS-MSW and DHS-G scenarios reduce the annual energy consumption of buildings by about 595 and 33 toes, respectively. Hence, the greenhouse gas effect will alleviate by mitigating the emission of 1403 and 1339 tons of CO2-eq./year, respectively. Moreover, exporting the extra natural gas through both LNG and pipeline provides about 26 million and 28 million USD/year revenue in DHS-G and DHS-MSW scenarios.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据