This prospective study used machine learning to quantitatively analyze fetal limb movement based on in-utero MRI images. The study found that maternal factors, such as increased oxygen levels, and fetal factors, such as gestational age, influenced the duration of fetal limb movements. The results showed longer movement time during maternal hyperoxia and a decrease in upper limb movement time with increasing gestational age while the lower limb movement time increased.
Early variations of fetal movements are the hallmark of a healthy developing central nervous system. However, there are no automatic methods to quantify the complex 3D motion of the developing fetus in-utero. The aim of this prospective study was to use machine learning (ML) on in-utero MRI to perform quantitative kinematic analysis of fetal limb movement, assessing the impact of maternal, placental, and fetal factors. In this cross-sectional, observational study, we used 76 sets of fetal (24-40 gestational weeks (GW)) blood oxygenation level-dependent (BOLD) MRI scans of 52 women (18-45 years old) during typical pregnancies. Pregnant women were scanned for 5 to 10 minutes while breathing room air (21% O2) and for 5 to 10 minutes while breathing 100% FiO2 in supine and/or lateral position. BOLD acquisition time was 20 minutes in total with an effective temporal resolution of approximately 3 seconds. To quantify upper and lower limb kinematics, we used a 3D convolutional neural network (CNN) previously trained to track fetal key points (wrists, elbows, shoulders, ankles, knees, hips) on similar BOLD time series. Tracking was visually assessed, errors manually corrected and the absolute movement time (AMT) for each joint was calculated. To identify variables that had a significant association with AMT, we constructed a mixed-model ANOVA with interaction terms. Fetuses showed significantly longer duration of limb movements during maternal hyperoxia. We also found a significant centrifugal increase of AMT across limbs and significantly longer AMT of upper extremities < 31 GW and longer AMT of lower extremities > 35 GW. In conclusion, using ML we successfully quantified complex 3D fetal limb motion in-utero and across gestation, showing maternal factors (hyperoxia) and fetal factors (gestational age, joint) impact movement. Quantification of fetal motion on MRI is a potential new biomarker of fetal health and neuromuscular development.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.2
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据