4.7 Article

Does perfect filtering really guarantee perfect phase correction for diffusion MRI data?

期刊

出版社

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.compmedimag.2022.102160

关键词

Phase correction; Noise-floor; Spatially-varying noise; Adaptive filtering

向作者/读者索取更多资源

Phase correction is used to reconstruct real-valued diffusion MRI data by estimating the noise-free background phase. However, signal-loss and artifacts can still occur. In this paper, we propose a complex polar coordinate system (CPCS) to analyze the phase correction procedure and identify its limitations. Based on CPCS, we develop a quantitative criterion to better exploit the background phase and propose a phase calibration procedure to improve phase correction. Experimental results on synthetic and real diffusion MRI data demonstrate the effectiveness of our proposed method in reducing signal-loss and eliminating artifacts in FA maps.
Owing to its merit of avoiding noise-floor, phase correction is recently used to reconstruct real-valued diffusion MRI data by employing an image filter to estimate the noise-free background phase. However, several studies report an unexpected signal-loss issue for their reconstruction results, with its causing reason still remaining unclear. Although phase correction has achieved promising results in mitigating the signal-loss issue via improving the employed image filter, we have observed counterintuitive results that an advanced filter generates severe artifacts in our previous work. Considering the potential issues with phase correction procedures, in this paper, we argue that even a perfect image filter is insufficient to produce perfect phase correction. To point out the reason why phase correction introduces signal-loss and address this issue, we first propose a complex polar coordinate system (CPCS) to analyze its procedures in detail; second, based on CPCS, we find that phase correction has not sufficiently utilized the background phase, and thus propose a quantitative criterion to fully exploit the background phase; eventually, we propose a phase calibration procedure to remedy current phase correction. Extensive experimental results, including those on synthetic and real diffusion MRI data, demonstrate that our proposed method significantly reduces signal-loss and also eliminates artifacts in FA maps, particularly with improved accuracy on FA.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据