4.0 Article

[18F]PSMA-1007 renal uptake parameters: Reproducibility and relationship to estimated glomerular filtration rate

期刊

CLINICAL PHYSIOLOGY AND FUNCTIONAL IMAGING
卷 43, 期 2, 页码 128-135

出版社

WILEY
DOI: 10.1111/cpf.12801

关键词

creatinine; DMSA; GFR; PET-CT; PSMA; renal cortex; renal function

向作者/读者索取更多资源

This study aimed to investigate the relationship between renal uptake of [F-18]PSMA-1007 and estimated glomerular filtration rate (eGFR). PET image analysis revealed a significant correlation between standardized uptake value (SUVmean) and segmentation volume of the kidneys with eGFR, indicating that [F-18]PSMA-1007 uptake parameters can serve as indicators of renal cortical function.
BackgroundScintigraphy with technetium-99m-labelled dimercaptosuccinic acid ([Tc-99m]Tc-DMSA) is widely used for renal cortical imaging. Uptake of [Tc-99m]Tc-DMSA has been shown to correlate with glomerular filtration rate (GFR). Prostate-specific membrane antigen (PSMA) radiopharmaceuticals used for positron emission tomography (PET) show high renal uptake and are being investigated for renal imaging. [Ga-68]Ga-PSMA-11 PET parameters have been shown to correlate with estimated GFR (eGFR). The aim of this study was to investigate the relationship between renal [F-18]PSMA-1007 uptake and eGFR. MethodsHundred and eighty-five patients underwent PET imaging at 1 and 2 h after injection of 4.0 +/- 0.2 MBq [F-18]PSMA-1007. Serum creatinine levels were measured and GFR estimated using the Chronic Kidney Disease Epidemiology Collaboration (CKD-EPI) and Modification of Diet in Renal Disease (MDRD) equations. Fifteen patients were excluded due to missing or incorrect data. Thus, data from 170 patients were analyzed. Kidneys were segmented in the PET images using a convolutional neural network with manual correction. For each kidney, mean standardized uptake value (SUVmean) and segmentation volume in millilitres were measured. Linear regression analyses were performed with eGFR as the outcome variable. ResultsVariation in the eGFR values was explained to a significant degree by SUVmean and renal segmentation volume in both the 1 and 2 h images. This correlation was stronger for CKD-EPI eGFR (1 h R-2 = 0.64; 2 h R-2 = 0.64) than for MDRD eGFR (1 h R-2 = 0.47; 2 h R-2 = 0.45). ConclusionRenal [F-18]PSMA-1007 uptake parameters correlate with eGFR and are indicative of renal cortical function.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.0
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据