4.5 Article

Effect of a novel interocclusal recording method on occlusal accuracy of implant-supported fixed prostheses: A randomized clinical trial

期刊

CLINICAL ORAL IMPLANTS RESEARCH
卷 34, 期 3, 页码 275-284

出版社

WILEY
DOI: 10.1111/clr.14040

关键词

bite registration; clinical effectiveness; dental implant therapy; implant-supported dental prosthesis; jaw relation record; occlusion

向作者/读者索取更多资源

This study investigated the effect of a novel interocclusal recording method on the occlusal accuracy of implant-supported fixed prostheses for partially dentate patients with distal extension. The results showed that the new method improved the accuracy of occlusal contacts and reduced the need for adjustment.
ObjectivesTo investigate the effect of a novel interocclusal recording method on the occlusal accuracy of implant-supported fixed prostheses for partially dentate patients with distal extension. Materials and MethodsTwenty patients with two or more adjacent teeth missing in the distal extension and scheduled to receive implant-supported fixed prostheses were enrolled. Two interocclusal recording methods were used: placing polyvinyl siloxane (PVS) on the interocclusal recording caps (test), and placing PVS on healing abutments (control). The intraoral occlusal contacts in maximal intercuspal position (MIP) were compared with those in the mounted casts to calculate sensitivity and positive predictive value (PPV). Then, patients were randomly allocated into two groups to determine which interocclusal record would be used. The implant prostheses' evaluations mainly included occlusal adjustment height, volume, and time, occlusal contact score based on articulating paper examination. Paired-samples t-test, Mann-Whitney U test, and least squares regression analyzed the statistic differences. ResultsThe test method had higher sensitivity to detect intraoral occlusal contacts than the control method (p = .002), but similar PPV (p = .10). During the prostheses' evaluations, the occlusal adjustment height in the test group was significantly lower than that in the control group [99.4 (53.2, 134.2) vs. 159.0 (82.3, 247.8) mu m, p = .03], while the occlusal contact score before adjustment was higher (p = .006). The groups had similar occlusal adjustment volume and time. ConclusionsThe novel interocclusal recording method for implant-supported fixed prostheses was more accurate and could reduce the occlusal adjustment.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据