4.5 Article

Influence of drilling sequence and guide-hole design on the accuracy of static computer-assisted implant surgery in extraction sockets and healed sites-An in vitro investigation

相关参考文献

注意:仅列出部分参考文献,下载原文获取全部文献信息。
Article Dentistry, Oral Surgery & Medicine

Influence of Metal Guide Sleeves on the Accuracy and Precision of Dental Implant Placement Using Guided Implant Surgery: An In Vitro Study

Coleman R. Adams et al.

Summary: This study compared the differences in implant position deviations between a digitally designed surgical guide with no metal sleeve and a conventional one with a metal sleeve. The results showed that the surgical guide without a metal sleeve demonstrated similar accuracy but higher precision compared to the one with a metal sleeve, suggesting that metal sleeves may not be necessary for guided surgery.

JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY (2023)

Article Dentistry, Oral Surgery & Medicine

Open-sleeve templates for computer-assisted implant surgery at healed or extraction sockets: An in vitro comparison to closed-sleeve guided system and free-hand approach

Junying Li et al.

Summary: This study investigated the accuracy of a buccal opening guide system. The results showed that open-sleeve sCAIS proved to be more accurate than free-hand surgery for both delayed and immediate implant placement. However, the closed-sleeve group showed fewer errors at healed sites, while the open-sleeve group exhibited fewer deviations in extraction sockets.

CLINICAL ORAL IMPLANTS RESEARCH (2022)

Article Dentistry, Oral Surgery & Medicine

Influence of bone density on the accuracy of artificial intelligence–guided implant surgery: An in vitro study

Zhicong Chen et al.

JOURNAL OF PROSTHETIC DENTISTRY (2022)

Article Dentistry, Oral Surgery & Medicine

Thermal exposure of implant osteotomies and its impact on osseointegration-A preclinical in vivo study

Raphael Heuzeroth et al.

Summary: This study found that using novel test drills with a shortened drill sequence resulted in lower maximum temperatures and shorter drill times during osteotomy preparation, leading to higher bone-to-implant contact and improved osseointegration compared to standard drills and conventional protocols.

CLINICAL ORAL IMPLANTS RESEARCH (2021)

Article Chemistry, Physical

In Vitro Comparison between Metal Sleeve-Free and Metal Sleeve-Incorporated 3D-Printed Computer-Assisted Implant Surgical Guides

Kyung Chul Oh et al.

Summary: This study compared the accuracy of metal sleeve-free and metal sleeve-incorporated 3D-printed computer-assisted implant surgical guides. Results showed that the metal sleeve-free guides had lower mesiodistal angular deviations in the left second premolars, indicating their feasibility for fully guided implant placement.

MATERIALS (2021)

Article Dentistry, Oral Surgery & Medicine

Comparison of the accuracy of implant placement using different drilling systems for static computer-assisted implant surgery: A simulation-based experimental study

Paknisa Sittikornpaiboon et al.

Summary: This in vitro study compared the accuracy of implant placement among five different surgical drilling systems for sCAIS, revealing significant differences in accuracy among the systems tested. The drilling protocol, devices used, and design principles of the guides could influence the accuracy of implant placement.

CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH (2021)

Article Dentistry, Oral Surgery & Medicine

Influence of implant macrodesign and insertion connection technology on the accuracy of static computer-assisted implant surgery

Karim El Kholy et al.

CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH (2019)

Article Dentistry, Oral Surgery & Medicine

Influence of surgical guide support and implant site location on accuracy of static Computer-Assisted Implant Surgery

Karim El Kholy et al.

CLINICAL ORAL IMPLANTS RESEARCH (2019)

Article Dentistry, Oral Surgery & Medicine

The influence of guided sleeve height, drilling distance, and drilling key length on the accuracy of static Computer-Assisted Implant Surgery

Karim El Kholy et al.

CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH (2019)

Article Dentistry, Oral Surgery & Medicine

Effectiveness of Contour Augmentation with Guided Bone Regeneration: 10-Year Results

V. Chappuis et al.

JOURNAL OF DENTAL RESEARCH (2018)

Review Dentistry, Oral Surgery & Medicine

The accuracy of static computer-aided implant surgery: A systematic review and meta-analysis

Ali Tahmaseb et al.

CLINICAL ORAL IMPLANTS RESEARCH (2018)

Article Dentistry, Oral Surgery & Medicine

Deviations of different systems for guided implant surgery

V. Laederach et al.

CLINICAL ORAL IMPLANTS RESEARCH (2017)

Article Dentistry, Oral Surgery & Medicine

Patient-reported outcome measures after routine periodontal and implant surgical procedures

Wah Ching Tan et al.

JOURNAL OF CLINICAL PERIODONTOLOGY (2014)

Review Engineering, Biomedical

Cortical bone drilling and thermal osteonecrosis

Goran Augustin et al.

CLINICAL BIOMECHANICS (2012)

Article Multidisciplinary Sciences

Heat-shock-induced cellular responses to temperature elevations occurring during orthopaedic cutting

E. B. Dolan et al.

JOURNAL OF THE ROYAL SOCIETY INTERFACE (2012)

Article Oncology

Thresholds for thermal damage to normal tissues: An update

Pavel S. Yarmolenko et al.

INTERNATIONAL JOURNAL OF HYPERTHERMIA (2011)

Review Dentistry, Oral Surgery & Medicine

The mental foramen and nerve: clinical and anatomical factors related to dental implant placement: A literature review

Gary Greenstein et al.

JOURNAL OF PERIODONTOLOGY (2006)