Commutability Assessment of Candidate Reference Materials for Lipoprotein(a) by Comparison of a MS-based Candidate Reference Measurement Procedure with Immunoassays

期刊

CLINICAL CHEMISTRY
卷 69, 期 3, 页码 262-272

出版社

OXFORD UNIV PRESS INC
DOI: 10.1093/clinchem/hvac203

关键词

-

向作者/读者索取更多资源

Elevated concentrations of Lp(a) are directly related to increased risk of cardiovascular diseases, but the lack of global standardization of current measurement procedures hinders consistent patient care. This study aims to develop a next-generation SI-traceable reference measurement system for Lp(a) using peptide-calibrated measurement procedures and serum-based reference materials. The results show that unspiked human serum pools are the preferred secondary reference materials for the future SI-traceable Lp(a) measurement system.
Background Elevated concentrations of lipoprotein(a) [Lp(a)] are directly related to an increased risk of cardiovascular diseases, making it a relevant biomarker for clinical risk assessment. However, the lack of global standardization of current Lp(a) measurement procedures (MPs) leads to inconsistent patient care. The International Federation for Clinical Chemistry and Laboratory Medicine working group on quantitating apolipoproteins by mass spectrometry (MS) aims to develop a next-generation SI (International system of units)-traceable reference measurement system consisting of a MS-based, peptide-calibrated reference measurement procedure (RMP) and secondary serum-based reference materials (RMs) certified for their apolipoprotein(a) [apo(a)] content. To reach measurement standardization through this new measurement system, 2 essential requirements need to be fulfilled: a sufficient correlation among the MPs and appropriate commutability of future serum-based RMs. Methods The correlation among the candidate RMP (cRMP) and immunoassay-based MPs was assessed by measuring a panel of 39 clinical samples (CS). In addition, the commutability of 14 different candidate RMs was investigated. Results Results of the immunoassay-based MPs and the cRMPs demonstrated good linear correlations for the CS but some significant sample-specific differences were also observed. The results of the commutability study show that RMs based on unspiked human serum pools can be commutable with CS, whereas human pools spiked with recombinant apo(a) show different behavior compared to CS. Conclusions The results of this study show that unspiked human serum pools are the preferred candidate secondary RMs in the future SI-traceable Lp(a) Reference Measurement System.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据