4.3 Article

Clinical and echocardiographic outcomes with new-onset left bundle branch block after SAPIEN-3 transcatheter aortic valve replacement

相关参考文献

注意:仅列出部分参考文献,下载原文获取全部文献信息。
Article Cardiac & Cardiovascular Systems

Membranous septum length predicts conduction disturbances following transcatheter aortic valve replacement

Ying-Hwa Chen et al.

Summary: This study suggests that preprocedural assessment of membranous septum length should be routinely adopted to determine the optimal implant depth, mitigating the risk of conduction disturbances after transcatheter aortic valve replacement (TAVR) with self-expanding valves.

JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY (2022)

Article Cardiac & Cardiovascular Systems

Membranous septum morphology and risk of conduction abnormalities after transcatheter aortic valve implantation

Troels Hojsgaard Jorgensen et al.

Summary: This study described the morphology of the membranous septum (MS) and predicted the risk of new conduction abnormalities (CA) after transcatheter aortic valve implantation (TAVI) based on the MS morphology and transcatheter heart valve (THV) implantation depth. The results showed that the depth of the MS and THV implantation depth measured at the anterior edge of the MS predicted the development of new CA after TAVI.

EUROINTERVENTION (2022)

Article Cardiac & Cardiovascular Systems

Systematic Approach to High Implantation of SAPIEN-3 Valve Achieves a Lower Rate of Conduction Abnormalities Including Pacemaker Implantation

Yasser Sammour et al.

Summary: The study showed that using a high deployment technique for the S3 valve can significantly reduce conduction abnormalities and permanent pacemaker requirement after transcatheter aortic valve replacement. The novel technique consistently achieves higher implantation without compromising procedural safety or valve hemodynamics in a cohort of 1028 patients.

CIRCULATION-CARDIOVASCULAR INTERVENTIONS (2021)

Review Cardiac & Cardiovascular Systems

Incidence, Predictors, and Implications of Permanent Pacemaker Requirement After Transcatheter Aortic Valve Replacement

Yasser Sammour et al.

Summary: Transcatheter aortic valve replacement (TAVR) is a safe alternative to surgery for patients with severe aortic stenosis, but conduction abnormalities requiring permanent pacemaker (PPM) implantation after the procedure are common and need to be carefully monitored. Research suggests that pre-existing conduction abnormalities may increase the risk of PPM implantation and mortality after TAVR.

JACC-CARDIOVASCULAR INTERVENTIONS (2021)

Article Cardiac & Cardiovascular Systems

Novel Anatomic Predictors of New Persistent Left Bundle Branch Block After Evolut Transcatheter Aortic Valve Implantation

Syed Zaid et al.

AMERICAN JOURNAL OF CARDIOLOGY (2020)

Article Cardiac & Cardiovascular Systems

The Utility of Rapid Atrial Pacing Immediately Post-TAVR to Predict the Need for Pacemaker Implantation

Amar Krishnaswamy et al.

JACC-CARDIOVASCULAR INTERVENTIONS (2020)

Article Medicine, General & Internal

Transcatheter Aortic-Valve Replacement with a Balloon-Expandable Valve in Low-Risk Patients

M. J. Mack et al.

NEW ENGLAND JOURNAL OF MEDICINE (2019)

Review Cardiac & Cardiovascular Systems

Management of Conduction Disturbances Associated With Transcatheter Aortic Valve Replacement JACC Scientific Expert Panel

Josep Rodes-Cabau et al.

JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY (2019)

Review Cardiac & Cardiovascular Systems

TAVI and Post Procedural Cardiac Conduction Abnormalities

Antonio Mangieri et al.

FRONTIERS IN CARDIOVASCULAR MEDICINE (2018)

Article Cardiac & Cardiovascular Systems

Aortic Annulus to Left Coronary Distance as a Predictor for Persistent Left Bundle Branch Block After TAVI

Ralph Hein-Rothweiler et al.

CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS (2017)

Editorial Material Cardiac & Cardiovascular Systems

Pacemaker Implantation After TAVR

Samir R. Kapadia et al.

JACC-CARDIOVASCULAR IMAGING (2017)

Article Cardiac & Cardiovascular Systems

The impact of trans-catheter aortic valve replacement induced left-bundle branch block on cardiac reverse remodeling

Laura E. Dobson et al.

JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE (2017)

Article Cardiac & Cardiovascular Systems

Clinical impact of a new left bundle branch block following TAVI implantation: 1-year results of the TAVIK cohort

Gerhard Schymik et al.

CLINICAL RESEARCH IN CARDIOLOGY (2015)

Article Cardiac & Cardiovascular Systems

Safety of a conservative strategy of permanent pacemaker implantation after transcatheter aortic CoreValve implantation

Marco De Carlo et al.

AMERICAN HEART JOURNAL (2012)

Article Cardiac & Cardiovascular Systems

Left Bundle-Branch Block Induced by Transcatheter Aortic Valve Implantation Increases Risk of Death

Patrick Houthuizen et al.

CIRCULATION (2012)

Article Cardiac & Cardiovascular Systems

Impact of a New Conduction Defect After Transcatheter Aortic Valve Implantation on Left Ventricular Function

Rainer Hoffmann et al.

JACC-CARDIOVASCULAR INTERVENTIONS (2012)