4.6 Article

Performance-based assessment of slender reinforced concrete columns typical of precast industrial buildings

期刊

BULLETIN OF EARTHQUAKE ENGINEERING
卷 21, 期 1, 页码 433-471

出版社

SPRINGER
DOI: 10.1007/s10518-022-01542-5

关键词

Slender RC columns; Precast structures; Plastic hinge length; Buckling; Industrial floor; Performance-based assessment

向作者/读者索取更多资源

This paper studied the non-linear response of slender columns by analyzing observed post-earthquake damage in Italy and Turkey, experimental data, and numerical predictions of failure patterns. The influence of foundation flexibility and the presence of industrial floor was also investigated. A simplified analytical methodology was proposed to predict the non-linear force-deformation response and possible failure mechanisms of slender precast columns. This research is important for seismic assessment and cost-efficient retrofit solutions for precast concrete industrial buildings.
Typically, the columns of the prefabricated reinforced concrete (RC) industrial buildings and warehouses with large clear storey heights are very slender, with aspect ratios (shear span to width) larger than 10. In addition to supporting the gravity loads, the columns also provide strength, stiffness, dissipation and displacement capacity of the primary lateral-load resisting system. However, current empirical relationships that predict the non-linear response and failure mechanisms of RC columns have been developed mainly for lower aspect ratios (< 7), typical of ordinary multi-storey buildings or short-to-medium bridge piers. What makes slender columns different is their predominant flexural response, larger drifts at nominal strength and corresponding lower ductility demands, smaller ratios between the strain penetration and plastic hinge lengths to the element shear span and risk of P-Delta instability. Therefore, the direct application of analytical models available in the literature to slender columns poses a risk of overestimation of their deformation and dissipative capacity. In turns this could lead to the underestimation of their displacement demand, overall damage and collapse probability of the primary seismic-resisting and load-bearing system. In the present research extensive analysis on the non-linear response of slender columns was performed based on observed post-earthquake damage to buildings in Italy and Turkey, experimental data and numerical predictions of the failure patterns through non-linear fiber element models. The influence of the foundation flexibility and the presence of industrial floor was also investigated. The outcome is a simplified analytical methodology for the prediction of the non-linear force-deformation response and possible failure mechanisms of slender precast columns due to rebar buckling or P-Delta effects, as a fundamental step towards the seismic assessment of the global structural performance and cost-efficient retrofit solutions for precast concrete industrial buildings.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据