4.6 Article

Three-layer model with absorption for conservative estimation of the maximum acoustic transmission coefficient through the human skull for transcranial ultrasound stimulation

期刊

BRAIN STIMULATION
卷 16, 期 1, 页码 48-55

出版社

ELSEVIER SCIENCE INC
DOI: 10.1016/j.brs.2022.12.005

关键词

Transcranial ultrasound stimulation (TUS); Ultrasonic neuromodulation (UNMOD); Focused ultrasound neuromodulation (FUN); Transcranial focused ultrasound (tFUS); Transcranial pulsed ultrasound (TPS); Low-intensity focused ultrasound (LIFUS)

向作者/读者索取更多资源

Transcranial ultrasound stimulation (TUS) is a safe and effective technique for non-invasive brain stimulation. However, there are no international guidelines for estimating the acoustic attenuation of the human skull. This study proposes a three-layer model to calculate the maximum pressure transmission through the human skull.
Transcranial ultrasound stimulation (TUS) has been shown to be a safe and effective technique for non-invasive superficial and deep brain stimulation. Safe and efficient translation to humans requires esti-mating the acoustic attenuation of the human skull. Nevertheless, there are no international guidelines for estimating the impact of the skull bone. A tissue independent, arbitrary derating was developed by the U.S. Food and Drug Administration to take into account tissue absorption (0.3 dB/cm-MHz) for diagnostic ultrasound. However, for the case of transcranial ultrasound imaging, the FDA model does not take into account the insertion loss induced by the skull bone, nor the absorption by brain tissue. Therefore, the estimated absorption is overly conservative which could potentially limit TUS applications if the same guidelines were to be adopted. Here we propose a three-layer model including bone ab-sorption to calculate the maximum pressure transmission through the human skull for frequencies ranging between 100 kHz and 1.5 MHz. The calculated pressure transmission decreases with the fre-quency and the thickness of the bone, with peaks for each thickness corresponding to a multiple of half the wavelength. The 95th percentile maximum transmission was calculated over the accessible surface of 20 human skulls for 12 typical diameters of the ultrasound beam on the skull surface, and varies between 40% and 78%. To facilitate the safe adjustment of the acoustic pressure for short ultrasound pulses, such as transcranial imaging or transcranial ultrasound stimulation, a table summarizes the maximum pressure transmission for each ultrasound beam diameter and each frequency. (c) 2022 Published by Elsevier Inc. This is an open access article under the CC BY-NC-ND license (http:// creativecommons.org/licenses/by-nc-nd/4.0/).

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据