期刊
BIORESOURCE TECHNOLOGY
卷 368, 期 -, 页码 -出版社
ELSEVIER SCI LTD
DOI: 10.1016/j.biortech.2022.128307
关键词
Sponge iron dosage; Nitrate removal; Microbial community; Reactor stability
This study found that the application of sponge iron (SI) in sequencing batch reactors (SBR) can improve the biochemical treatment performance during wastewater treatment, especially at low temperature and ultra-low load conditions.
The application of sponge iron (SI) carriers can improve the biochemical treatment performance of sequencing batch reactors (SBR) during wastewater treatment. This study used SBR reactors to explore the effects of SI dosage on the nitrogen removal performance and reactor stability and microbial community structure under low temperature and ultra-low load. In contrast to conventional SBR, the average removal rate of total nitrogen (TN) in the biological sponge iron system (BSIS) was increased by 5.38 % for 45 g/L, 18.93 % for 90 g/L, and 13.52 % for 135 g/L, respectively. The nitrogen removal performance and reactor stability showed the best performance under the SI dosage of 90 g/L. The addition of SI formed the anaerobic-anoxic-aerobic microenvironments, which facilitate the propagation of denitrifying bacteria (Saccharimonadales, Hydrogenophaga) and iron bacteria (Rhodoferax and Acinetobacter) in the BSIS. This study provides a new insight on the application of SI in the wastewater treatment.
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。
推荐