4.6 Article

Automatic 3D mitral valve leaflet segmentation and validation of quantitative measurement

期刊

出版社

ELSEVIER SCI LTD
DOI: 10.1016/j.bspc.2022.104166

关键词

Mitral valve; Image segmentation; Deep learning; Quantitative measurement; Pre-training

向作者/读者索取更多资源

The aim of this study was to achieve automatic segmentation of patient-specific 3D transesophageal echocardiography (TEE) mitral valve leaflets without user interaction and to evaluate the feasibility of quantitative measurements on the automatic segmentation model. A novel pre-training strategy was proposed to improve the segmentation performance. The results showed that the automatic segmentation model had a good agreement with the clinical software in most mitral annular parameters, indicating its reliability for quantitative measurements.
3D transesophageal echocardiography (TEE) is widely used in the diagnosis of mitral valve disease and is also well suited for guiding cardiac interventions. The aim of this work is to achieve patient-specific 3D TEE mitral valve leaflet segmentation without any user interaction and to assess the feasibility of 3D quantitative measurements on automatic segmentation model. We suggested a novel pre-training strategy to better implement automatic segmentation. The strategy refers to classify the diastolic and systolic states of the mitral valve through a 3D convolutional neural network architecture, and then use the pretrained weights obtained from the classification task to initialize the parameters of the 3D segmentation deep learning framework. To determine the accuracy of geometric parameters of segmentation model, the measurements of the segmentation model were compared with those obtained by the clinical software. Statistical analysis was performed by using Intraclass Correlation Coefficient and Bland-Altman method. Fourteen 3D volumes were used to evaluate the segmentation performance. The results show a Dice Similarity Coefficient (DSC) of 0.877 +/- 0.027 and an Average Surface Distance (ASD) of 0.925 +/- 0.392 mm. Twenty-eight 3D volumes were used for the quantitative measurement. The statistical results show that the mitral annular parameters have a good agreement between segmentation model and clinical software except for the annular height. We developed a fully automatic methodology to segment the mitral valve leaflet from 3D TEE and demonstrated the feasibility of improving segmentation performance with the proposed pre-training strategy. The automatic segmentation model was proved to be reliable for performing quantitative measurements of mitral valve annulus dimensions. The results indicate that the precision of the automatic segmentation methodology could pave the way for application in quantification, modeling and surgical planning tools.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据