4.6 Article

Data reduction and restoration of spectropolarimetric microlensed hyperspectral imager data

期刊

ASTRONOMY & ASTROPHYSICS
卷 668, 期 -, 页码 -

出版社

EDP SCIENCES S A
DOI: 10.1051/0004-6361/202243466

关键词

techniques; high angular resolution; image processing; imaging spectroscopy; polarimetric; methods; data analysis; observational

资金

  1. European Commission's FP7 Capacities Program [212482, 312495]
  2. European Union [653982, 824135]

向作者/读者索取更多资源

A new data reduction procedure is needed to convert raw data frames of MiHI to hyperspectral cubes and restore them to high-resolution science-ready Stokes data. The extracted and restored data were found to have a similar spatial resolution to the equivalent data from the context imager, while maintaining a spectral resolution of approximately 300,000.
Context. A microlensed hyperspectral imager (MiHI) is an integral field spectrograph based on a double-sided microlens array.Aims. To convert the raw data frames of such an instrument to hyperspectral cubes, and restore them to high-resolution science-ready Stokes data, a new kind of data reduction procedure is required.Methods. An optimized ad hoc transfer map of a MiHI prototype was used to convert the raw data into raw hyperspectral form. The transfer map was modified to match the position of the image on the detector, which was found to drift considerably during the course of an observing day. The determination of this position was used to move the recorded flat-field images to the position of the observation, which was found to be a critical step in the accurate gain correction of the raw data cubes. The converted data were found to be suitable for image restoration but still contained unwanted polarimetric structure that needed to be removed.Results. The extracted and restored data were found to be of a similar spatial resolution as the equivalent data from the context imager, while retaining a spectral resolution of approximately 300 000. The noise properties of the raw data were determined by the photon statistics and were found to be consistent with the estimated transparency of the instrument and the integration time of the image sensor. As for all image-restored data, the noise properties of the restored data were found to be dependent on the instrumental and atmospheric point spread function. An attempt to compare the data to other similar data suggested that the data had a spectral and spatial information content comparable to that of a Hinode spectro-polarimetric scan, but with a higher spatial resolution and a temporal cadence of approximately 10s.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据