Experimental mass and heat transfer at a serpentine tube heat exchanger located at the wall of a square stirred tank reactor

期刊

APPLIED THERMAL ENGINEERING
卷 219, 期 -, 页码 -

出版社

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.applthermaleng.2022.119438

关键词

Mass transfer; Heat transfer; Serpentine tube; Heat exchanger; Immobilized cell or enzyme reactor; Electrochemical reactor

向作者/读者索取更多资源

This study investigates the mass and heat transfer behavior of a serpentine tube heat exchanger located at the wall of a square stirred tank reactor using the electrochemical technique. The results show that factors such as impeller rotational speed, impeller geometry, tube diameter, and tube pitch affect the mass or heat transfer coefficients. It is also found that the serpentine tube heat exchanger has higher mass transfer rates and can be used as a catalyst support and cooler, reducing the costs of biochemical reactors.
Although the study of the heat transfer behavior of stirred tank heat exchangers such as helical coils, vertical tube baffles, and cooling jackets has received much attention, no study has been reported on the heat or mass transfer behavior of serpentine tube heat exchangers, so the present work aims to study rates of mass and heat transfer (by analogy) at the outer surface of a serpentine tube heat exchanger located at the wall of a square stirred tank reactor by the electrochemical technique. Variables studied were impeller rotational speed, impeller geometry, tube diameter, and tube pitch. The mass or heat transfer coefficients were found to increase with increasing impeller speed and decrease with increasing cylinder diameter and pitch. For a given set of conditions, a radial flow turbine produces higher rates of mass transfer than an axial flow turbine. The data were correlated by dimensionless mass transfer correlations which can be used to scale up and operate the heat exchanger. When the mass transfer data at the serpentine tube were compared with those at an active flat wall of equal height, it was found that the mass transfer rate at the serpentine tube is higher than that of the flat wall by an amount ranging from 10% to 210% depending on the operating conditions. The possibility of using the serpentine tube as a catalyst support for conducting diffusion-controlled exothermic immobilized cell biochemical reactions which need rapid cooling to avoid thermal degradation of the biomass was highlighted. The dual-use of the serpentine tubes as a catalyst support and a cooler would reduce the capital and operating costs of immobilized enzyme or cell stirred tank biochemical reactors compared, for instance, with the traditional stirred slurry reactor owing to the elimination of the costly and time-consuming process of separating the final product from the catalyst particles.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据