4.7 Article

Influence of different magnetic field profiles on the performance of a rotary magnetic refrigerator

期刊

APPLIED THERMAL ENGINEERING
卷 219, 期 -, 页码 -

出版社

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.applthermaleng.2022.119561

关键词

Active magnetic regenerator; Magnetic field profile; Blow fraction; Experimental research

向作者/读者索取更多资源

In magnetic refrigerators, the operation profiles, including flow profile and magnetic field profile, significantly affect system performance. This study focuses on the influence of magnetic field profile in a rotary magnetic refrigerator. Experimental investigation reveals that the intermittent magnetic field profile outperforms the continuous profile in terms of temperature span and cooling power at frequencies of 0.25, 0.40, and 0.55 Hz. Moreover, a higher temperature span of 22.7 K is achieved with the intermittent profile at a frequency of 0.55 Hz and a utilization factor of 0.52 compared to the continuous profile. Furthermore, a comprehensive study of three blow fractions (0.35, 0.5, and 0.65) for a better intermittent profile demonstrates that the increase in blow fraction leads to a slight improvement in temperature span and cooling power.
In magnetic refrigerators, operation profiles (including flow profile and magnetic field profile) have great influence on system performance. This paper focuses on the study of the influence of the magnetic field profile in a rotary magnetic refrigerator. Based on the operating modes of the magnet, the magnetic field profile can be separated into two kinds: continuous and intermittent profiles. Firstly, the effects of two profiles on the active magnetic regenerator were experimentally studied. The temperature span, cooling power, power consumption (the direct magnet-driving power plus the fluid-pumping power) and COP were compared. At a fixed flow profile of 0.5 blow fraction, the intermittent profile has better performance in terms of temperature span and cooling power than the continuous profile at frequencies of 0.25, 0.40 and 0.55 Hz. When the frequency and utilization factor was 0.55 Hz and 0.52 respectively, a maximum temperature span of 22.7 K was achieved by the intermittent profile, which was 2 K bigger than the continuous profile. Then, a comprehensive research of three blow fractions (0.35, 0.5 and 0.65) was done for a better intermittent profile. When the blow fraction increased from 0.35 to 0.65, the temperature span and cooling power slightly increased. The experimental results showed a complicated relationship between the blow fraction and COP, which depended on the utilization factor. Typically, when the temperature span was 10 K at 0.40 Hz and 0.52 utilization factor, the COP decreased from 7.64 to 6.43 with the increase of blow fraction from 0.35 to 0.6.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据