4.5 Article

Optical Vernier sensor based on a cascaded tapered thin-core microfiber for highly sensitive refractive index sensing

期刊

APPLIED OPTICS
卷 61, 期 36, 页码 10727-10734

出版社

Optica Publishing Group
DOI: 10.1364/AO.478831

关键词

-

类别

资金

  1. National Natural Science Foundation of China
  2. Chongqing Talents Program
  3. Key Project of Science and Technology Research of Chongqing Education Commission
  4. Graduate Student Innovation Program of Chongqing University of Technology
  5. [61875026]
  6. [CSTC2021YCJH-BGZXM0128]
  7. [CSTC2021YCJH-BGZXM0287]
  8. [KJZD-K202201106]
  9. [KJZD-K201901101]
  10. [gzlcx20223050]

向作者/读者索取更多资源

This study proposes a refractive index sensor using a cascaded tapered thin-core microfiber based on the Vernier effect. The sensor provides high sensitivity measurements with a simple structure and low-temperature cross sensitivity, making it suitable for applications in biosensing fields.
This study proposes a refractive index (RI) sensor using a cascaded tapered thin-core microfiber (TTCMF) based on the Vernier effect. The thin-core fiber was made into a TTCMF by arc discharging and flame heating and then sandwiched between two single-mode fibers (SMFs). The two structures with the same SMF-TTCMF-SMF but slightly different free spectral ranges (FSRs) were cascaded to generate the Vernier effect. The FSR varied with the taper parameters of TTCMF. The RI sensitivities of a single TTCMF sensor, series SMF-TTCMF-SMF sensor, and parallel SMF-TTCMF-SMF sensor were compared and analyzed. Using the Vernier effect in the RI measure-ment range from 1.3313 to 1.3392, a very high RI sensitivity of -15, 053.411 nm/RIU was obtained using the series SMF-TTCMF-SMF structure, and -16, 723.243 nm/RIU using the parallel structure, which were basi-cally consistent with the simulation results. Compared with the RI sensitivity of the single TTCMF sensor, the RI sensitivities of series and parallel sensors were increased by 4.65 times and 5.16 times, respectively. In addition, in the temperature range from 35 degrees C to 65 degrees C, temperature sensitivities of -0.196 nm/degrees C and -0.0489 nm/degrees C were obtained using series and parallel structures, respectively; the corresponding temperature cross errors were 1.302 x 10-5 RIU/degrees C and 2.92 x 10-6 RIU/degrees C, respectively. Based on the advantages of high RI sensitivity, simple structure, low-temperature cross sensitivity, and convenient fabrication, the proposed sensors have great potential in biosensing fields.(c) 2022 Optica Publishing Group

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据