4.8 Article

Compatibility investigation and techno-economic performance optimization of whole geothermal power generation system

期刊

APPLIED ENERGY
卷 328, 期 -, 页码 -

出版社

ELSEVIER SCI LTD
DOI: 10.1016/j.apenergy.2022.120165

关键词

Pinnate horizontal well; Geothermal power generation; Compatibility optimization; Operation strategy

资金

  1. National Key R&D Program of China
  2. [2018YFB1501805]

向作者/读者索取更多资源

Appropriate compatibility between exploitation and utilization systems is critical for geothermal electricity. This study proposes a potential enhanced geothermal system (EGS) that incorporates three typical power generation systems for electricity generation. The results indicate that the proposed system is more compatible and economical compared to other systems.
Appropriate compatibility between exploitation and utilization systems is of critical importance to geothermal electricity. However, few research works focused on the optimal dynamic matching between subsurface heat extraction system and surface power generation system according to the dynamic process of enhanced geothermal system (EGS). In present work, a potential EGS with pinnate horizontal well is proposed to generate electricity by incorporating three typical power generation systems, namely single-flash (SF) system, double-flash (DF) system and single-flash with organic Rankine cycle (SFORC) system. System coupling is achieved to explore the optimum operation strategy of surface power generation system by considering the dynamic characteristics of geothermal fluid temperature and flow rate. The reliability of numerical method and thermodynamic model used in present work are validated by the theoretical model. Furthermore, the response surface methodology is employed to optimize the operation strategy of proposed EGS. Based on the maximization of exergy efficiency and minimization of total cost, the optimum running strategies and techno-economic performance of proposed power generation systems are obtained, respectively. The results indicate that temperature drop of thermal reservoir is significantly affected by the combined effect of injection flow rate and reservoir permeability. The net output exergy is proportional to branch well length and reservoir permeability, and inversely proportional to the injection temperature and injection flow rate. Compared with the SF and DF systems, SFORC system is more compatible and economical to be applied in the proposed EGS. After 30 years of operating, the net revenue of SFORC system can reach to 2.66 x 108 USD, which are 2.30 and 1.02 times more than those of SF and DF systems, respectively. The corresponding flash temperature of SFORC is the same as production temperature of the EGS. Meanwhile, the evaporation temperature of n-pentane will drop in four steps from 405.15 K to 399.15 K.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.8
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据