Comparative studies on air borne noise and flow induced noise of a double suction centrifugal pump

期刊

APPLIED ACOUSTICS
卷 202, 期 -, 页码 -

出版社

ELSEVIER SCI LTD
DOI: 10.1016/j.apacoust.2022.109148

关键词

Air born noise (ABN); Blade pass frequency (BPF); Centrifugal pump; Double suction; Flow induced noise (FIN); Pressure fluctuations

向作者/读者索取更多资源

This paper presents a comparative study on the Air Borne Noise (ABN) and Flow Induced Noise (FIN) of a double suction centrifugal pump. The study includes experiments and numerical simulations to explore the relationship between FIN and ABN, as well as the prediction methods for FIN and ABN.
The Flow Induced Noise (FIN) of a centrifugal pump directly affects the Air Borne Noise (ABN) of the same. But, the information regarding focus on ABN of a pump in relation to its FIN is very scarce. This paper presents the comparative study performed on the ABN and FIN of a double suction centrifugal pump. Experiments were conducted on a double suction pump of specific speed (ns) 19 to measure ABN. Free field noise measurements for ABN, aligning with the industrial standards were conducted using FFT ana-lyzer for 3 speeds such as 990 rpm, 1200 rpm, and 1450 rpm. For each speed, the normalized flow ratio (QQn) covered were 0.4, 0.6, 0.8, 1 and 1.2 for measurements. For FIN prediction, transient numerical sim-ulations were conducted for the same pump at 990 & 1450 rpm. Detached Eddy Simulation (DES) and Fast Fourier Transform (FFT) were used to understand the noise generation at the blade passing frequency (BPF) and the variation of discharge flow recirculation in impeller outlet at different speeds. Moreover, for FIN, a generalized quadratic equation with parabolic form is derived for a speed of 1450 rpm. Also, the derived equation at 1450 rpm has been used to develop a relation to predict the FIN at other speeds. Further, the derived FIN relations are used to predict the ABN at different speeds by expressing ABN in terms of FIN for particular speed. Overall, the developed FIN function is useful in predicting the FIN in dB at BPF of a double suction pump for impeller Reynolds number and specific speeds in ranges 2.7 * 106 <= Re <= 8.2 * 106 and 19 <= ns <= 52 respectively with error ranging from +7.5 % to-7.5 %. Empirical correlation is also developed to predict the FIN with error ranging from +6 % to-6%, where FIN was the function of structural (geometrical) parameters and hydraulic (fluid and flow) parameters of the pump. Also, the methodology is used to predict ABN at BPF from the calculated FIN for that partic-ular speed with error ranging from-2.5 % to +2.5 %. (c) 2022 Elsevier Ltd. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据