4.3 Article

Comparison of Open-Access, Trough-Only Online Calculators Versus Trapezoidal Method for Calculation of Vancomycin Area Under the Curve (AUC)

期刊

ANNALS OF PHARMACOTHERAPY
卷 57, 期 8, 页码 940-947

出版社

SAGE PUBLICATIONS INC
DOI: 10.1177/10600280221138867

关键词

vancomycin; Bayesian kinetics; therapeutic monitoring; pharmacokinetics; pharmacodynamics

向作者/读者索取更多资源

This study compared the accuracy of vancomycin AUC calculated by open-access, online, trough-only calculators to AUCs calculated by the trapezoidal method using peak and trough concentrations. The results showed that VancoPK was the closest calculator to the trapezoidal method and had the most consistent dose adjustments. Therefore, VancoPK can be used as an alternative to the trapezoidal method for calculating vancomycin AUC.
Background: Vancomycin area-under-the-curve (AUC) monitoring is associated with reduced nephrotoxicity but may increase cost and workload for personnel compared to trough monitoring. Objective: The purpose of this study was to compare the accuracy of vancomycin AUC calculated by open-access, online, trough-only calculators to AUCs calculated by the trapezoidal method (TM) using peak and trough concentrations. Methods: This retrospective, multi-center study included adults >= 18 years old with stable renal function who received vancomycin with steady-state peak and trough concentrations. Areas under the curve calculated by TM were compared to AUCs calculated by 3 online calculators using trough-only options for calculation: ClinCalc, VancoVanco, and VancoPK. The primary outcome was actual difference in AUC between TM and the online calculators. Secondary outcomes were percent difference in AUC and clinical alignment in dose adjustments between methods. Results: Seventy patients were included for analysis. There was a statistically significant difference in AUC between TM and ClinCalc (median actual difference: -52, P < 0.001) and VancoVanco (median actual difference: 95, P < 0.001), whereas there was no significant difference between TM and VancoPK (median actual difference: -0.8, P = 0.827). Discordant dose adjustments were indicated when comparing ClinCalc, VancoVanco, and VancoPK to TM in 28%, 36%, and 12% of cases, respectively. Conclusion: The AUC calculator most closely aligned with TM was VancoPK, whereas other included calculators were statistically different. Owing to the cost and complexity of obtaining multiple levels, our findings support using a single steady-state trough using VancoPK as an alternative to TM for calculation of vancomycin AUC.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.3
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据