4.7 Article

A Race-neutral Approach to the Interpretation of Lung Function Measurements

出版社

AMER THORACIC SOC
DOI: 10.1164/rccm.202205-0963OC

关键词

spirometry; racial groups; health equity

向作者/读者索取更多资源

This study aims to develop a race-neutral reference equation for interpreting lung function measurements. By reanalyzing the NHANES III data and GLI data, it was found that incorporating sitting height and Cormic index slightly improved the statistical precision of the reference equations but did not explain the differences in lung function between racial and ethnic groups. Therefore, the use of GLI global equations can better reflect the variations in lung function among different populations.
Rationale: The use of self-reported race and ethnicity to interpret lung function measurements has historically assumed that the observed differences in lung function between racial and ethnic groups were because of thoracic cavity size differences relative to standing height. Very few studies have considered the influence of environmental and social determinants on pulmonary function. Consequently, the use of race and ethnicityspecific reference equations may further marginalize disadvantaged populations. Objectives: To develop a race-neutral reference equation for spirometry interpretation. Methods: National Health and Nutrition Examination Survey (NHANES) III data (n = 6,984) were reanalyzed with sitting height and the Cormic index to investigate whether body proportions were better predictors of lung function than race and ethnicity. Furthermore, the original GLI (Global Lung Function Initiative) data (n = 74,185) were reanalyzed with inverse-probability weights to create race-neutral GLI global (2022) equations. Measurements and Main Results: The inclusion of sitting height slightly improved the statistical precision of reference equations compared with using standing height alone but did not explain observed differences in spirometry between the NHANES III race and ethnic groups. GLI global (2022) equations, which do not require the selection of race and ethnicity, had a similar fit to the GLI 2012 other equations and wider limits of normal. Conclusions: The use of a single global spirometry equation reflects the wide range of lung function observed within and between populations. Given the inherent limitations of any reference equation, the use of GLI global equations to interpret spirometry requires careful consideration of an individual's symptoms and medical history when used to make clinical, employment, and insurance decisions.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据