4.3 Article

High-sensitivity double-parameter sensor based on the fibre-tip Fabry-Perot interferometer

期刊

JOURNAL OF MODERN OPTICS
卷 64, 期 6, 页码 596-600

出版社

TAYLOR & FRANCIS LTD
DOI: 10.1080/09500340.2016.1252437

关键词

Fabry-Perot interferometer; polydimethylsiloxane; double-parameter sensor

类别

资金

  1. National Science Foundation of China [11304064, 11304065]
  2. Science and Technology Foundation of Shandong Province [ZR2013AQ002]
  3. National Key Technology R&D Program - Special Scientific Research Found of Public Service industry of Quality Inspection [2014BAA02B03, 201410030-03]

向作者/读者索取更多资源

We have proposed an ultra-compact double polymer-capped Fabry-Perot interferometer (FPI), which could be used for simultaneously measuring refractive index (RI) and temperature with low cross sensitivity. The designed and fabricated FPIs have double polymer layers which were fabricated by step-curing ultraviolet photoresist (SU-8) and polydimethylsiloxane on the end face of a traditional single-mode fibre. Three samples were fabricated with different Fabry-Perot cavity lengths. Experimental results show that the double polymer structure has higher temperature and RI sensitivities than single-layer structure. About 689.68pm/degrees C (based on the wavelength shift) in the temperature range of 20-75 degrees C and -147.04dB/RIU (based on peak intensity measurement) in the RI range of 1.335-1.355 were measured, respectively. Moreover, the compact structure, high temperature sensitivity and low cross-sensitivity of the FPI make it suitable for integration such as biomedical and microfluidic sensor probe.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.3
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据