4.5 Article

Evaluating Fouling Control and Energy Consumption in a Pilot-Scale, Low-Energy POREFLON Non-Aerated Membrane Bioreactor (LEP-N-MBR) System at Different Frequencies and Amplitudes

期刊

MEMBRANES
卷 12, 期 11, 页码 -

出版社

MDPI
DOI: 10.3390/membranes12111085

关键词

LEP-N-MBR; frequency; amplitude; nutrient removal; energy consumption

向作者/读者索取更多资源

A pilot-scale LEP-N-MBR system, a low-energy non-aerated membrane bioreactor, was designed and operated to evaluate its energy usage and membrane fouling. The results showed that adjusting the frequency and amplitude could reduce energy consumption and membrane fouling. The LEP-N-MBR system has great potential and effectiveness for municipal wastewater treatment, but further operational optimization is needed.
Continual aeration, a fouling control strategy that causes high energy consumption, is the major obstacle in the deployment of membrane bioreactors (MBRs) for wastewater treatment. In recent years, a technology has been developed which adopts mechanical reciprocity for membrane vibration, and it has been proven efficient for membrane scouring, as well as for saving energy: the low-energy POREFLON non-aerated membrane bioreactor (LEP-N-MBR). In this study, a pilot-scale LEP-N-MBR system was designed, established, and operated at various frequencies and amplitudes, and with various membrane models, so as to evaluate energy usage and membrane fouling. The results showed that a slower TMP rise occurred when the frequency and amplitude were set to 0.5 Hz and 10 cm, respectively. Under a suitable frequency and amplitude, the TMP increasing rate of model B (sealed only with epoxy resin) was slower than that of model A (sealed with a combination of polyurethane and epoxy resin). The average specific energy demand (SED) of the LEP-N-MBR was 0.18 kWh center dot m(-3), much lower than the aerated MBR with 0.43 kWh center dot m(-3) (obtained from a previous study), indicating a significant decrease of 59.54% in the SED. However, the uneven distribution of sludge within the membrane tank indicated that the poor hydraulic mixing in the reactor may result in sludge accumulation, which requires further operational optimization. The findings of this pilot-scale study suggest that the LEP-N-MBR system is promising and effective for municipal wastewater treatment with a much lower level of energy usage. More research is needed to further optimize the operation of the LEP-N-MBR for wide application.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据