4.3 Article

In situ-forming PLGA implants loaded with leuprolide acetate/-cyclodextrin complexes: mathematical modelling and degradation

期刊

JOURNAL OF MICROENCAPSULATION
卷 33, 期 4, 页码 355-364

出版社

TAYLOR & FRANCIS LTD
DOI: 10.1080/02652048.2016.1194905

关键词

In situ-forming implant; PLGA; leuprolide acetate; -cyclodextrin complexes; mathematical modelling; degradation

资金

  1. Varian Pharmed Company

向作者/读者索取更多资源

Drug release mechanism of in situ-forming implants (ISIs) based on poly(lactic acid-co-glycolic acid) (PLGA) loaded with leuprolide acetate/-cyclodextrin (LA/-CD) complexes via fitting with four diffusion-based semi-empirical models were studied. The release rate constants and release exponent of ISIs were calculated. The main drug release mechanism was Fickian diffusion. The LA diffusion coefficient and release constant were decreased via increasing the portion of -CD in complexes. The release curve was parabolic, with a higher initial slope and then consistent with the exponential. All ISIs containing LA/-CD complexes better fitted with the Korsmeyer-Peppas, Weibull and Peppas-Sahlin models rather than first-order model. Furthermore, the effect of LA/-CD complexation on the degradation of ISIs was studied through scanning electron microscopy (SEM). Results showed that hydrophilic nature of -CD facilitated the surface erosion of PLGA chains, however after 18 d, ISI-1/10 had still a proper structural strength, due to no hydrolytic degradation of -CD in this implant.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.3
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据