4.3 Article

Direct loop mediated isothermal amplification on filters for quantification of Dehalobacter in groundwater

期刊

JOURNAL OF MICROBIOLOGICAL METHODS
卷 131, 期 -, 页码 61-67

出版社

ELSEVIER SCIENCE BV
DOI: 10.1016/j.mimet.2016.09.025

关键词

Gene-Z; Dehalobacter; Real-time loop mediated isothermal amplification; Direct filter amplification; Field-able genetic diagnostics; Point-of-use; Groundwater

资金

  1. United States Department of Defense Strategic Environmental Research and Development Program (SERDP) [ER-2309]
  2. Environmental Protection Agency Great Lakes Restoration Initiative [GL-00E01127-0]
  3. National Institute for Environmental Health Sciences [2 P42 ES004911-22A1]

向作者/读者索取更多资源

Nucleic acid amplification of biomarkers is increasingly used to monitor microbial activity and assess remedial performance in contaminated aquifers. Previous studies described the use of filtration, elution, and direct isothermal amplification (i.e. no DNA extraction and purification) as a field-able means to quantify Dehalococcoides spp. in groundwater. This study expands previous work with direct loop mediated isothermal amplification (LAMP) for the detection and quantification of Dehalobacter spp. in groundwater. Experiments tested amplification of DNA with and without crude lysis and varying concentrations of humic acid. Three separate field-able methods of biomass concentration with eight aquifer samples were also tested, comparing direct LAMP with traditional DNA extraction and quantitative PCR (qPCR). A new technique was developed where filters were amplified directly within disposable Gene-Z chips. The direct filter amplification (DFA) method eliminated an elution step and provided a detectipn limit of 102 Dehalobacter cells per 100 mL LAMP with crudely lysed Dehalobacter had a negligible effect on threshold time and sensitivity compared to lysed samples. The LAMP assay was more resilient than traditional qPCR to humic acid in sample, amplifying with up to 100 mg per L of humic acid per reaction compared to 1 mg per L for qPCR. Of the tested field-able concentrations methods, DFA had the lowest coefficient of variation among Dehalobacter spiked groundwater samples and lowest threshold time indicating high capture efficiency and low inhibition. While demonstrated with Dehalobacter, the DFA method can potentially be used for a number of applications requiring field-able, rapid (<60 min) and highly sensitive quantification of microorganisms in environmental water samples. (C) 2016 Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.3
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据