4.7 Article

An estimate assay for low-level exposure to ionizing radiation based on mass spectrometry quantification of gamma-H2AX in human peripheral blood lymphocytes

期刊

FRONTIERS IN PUBLIC HEALTH
卷 10, 期 -, 页码 -

出版社

FRONTIERS MEDIA SA
DOI: 10.3389/fpubh.2022.1031743

关键词

low-dose exposure; ionizing radiation; gamma-H2AX; human peripheral blood lymphocytes; mass spectrometry

资金

  1. Youth Program of National Natural Science Foundation of China [31800704]
  2. Continuous Basic Scientific Research Project [WDJC-2019-11]
  3. [BWS18J008]

向作者/读者索取更多资源

The study demonstrates the accuracy and potential utility of using mass spectrometry to quantify gamma-H2AX in human peripheral blood cells for assessing low-dose exposure to IR.
Exposure to environmental ionizing radiation (IR) is ubiquitous, and large-dose exposure to IR is known to cause DNA damage and genotoxicity which is associated with an increased risk of cancer. Whether such detrimental effects are caused by exposure to low-dose IR is stilt debated. Therefore, rapid and early estimation of absorbed doses of IR in individuals, especially at low levels, using radiation response markers is a pivotal step for early triage during radiological incidents to provide adequate and timely clinical interventions. However, there is currently a crucial shortage of methods capable of determining the extent of low-dose IR exposure to human beings. The phosphorylation of histone H2AX on serine 139 (designated gamma-H2AX), a classic biological dosimeter, can be used to evaluate the DNA damage response. We have developed an estimation assay for low-level exposure to IR based on the mass spectrometry quantification of gamma-H2AX in blood. Human peripheral blood lymphocytes sensitive to low-dose IR, maintaining low temperature (4 degrees C) and adding enzyme inhibitor are proven to be key steps, possibly insuring that a stable and marked gamma-H2AX signal in blood cells exposed to low-dose IR could be detected. For the first time, DNA damage at low dose exposures to IR as low as 0.01 Gy were observed using the sensitive variation of gamma-H2AX with high throughput mass spectrometry quantification in human peripheral blood, which is more accurate than the previously reported methods by virtue of isotope-dilution mass spectrometry, and can observe the time effect of DNA damage. These in vitro cellular dynamic monitoring experiments show that DNA damage occurred rapidly and then was repaired slowly over the passage of post-irradiation time even after exposure to very low IR doses. This assay was also used to assess different radiation exposures at the in vitro cellular level. These results demonstrate the potential utility of this assay in radiation biodosimetry and environmental risk assessment.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据