4.5 Article

Validating a Portable Device for Blinking Analyses through Laboratory Neurophysiological Techniques

期刊

BRAIN SCIENCES
卷 12, 期 9, 页码 -

出版社

MDPI
DOI: 10.3390/brainsci12091228

关键词

blinking movements; neurophysiology; portable device; kinematic analysis

资金

  1. Blinktbi, Inc., Charleston, SC, USA

向作者/读者索取更多资源

Blinking analysis contributes to understanding the physiological and pathophysiological mechanisms of healthy subjects and neurological diseases. Comparing blinking data recorded by a new portable device, EyeStat, with traditional laboratory-based techniques, we found high accuracy and reliability in the analysis, suggesting its potential for large-scale studies in both research and clinical practice.
Blinking analysis contributes to the understanding of physiological mechanisms in healthy subjects as well as the pathophysiological mechanisms of neurological diseases. To date, blinking is assessed by various neurophysiological techniques, including electromyographic (EMG) recordings and optoelectronic motion analysis. We recorded eye-blink kinematics with a new portable device, the EyeStat (Generation 3, blinktbi, Inc., Charleston, SC, USA), and compared the measurements with data obtained using traditional laboratory-based techniques. Sixteen healthy adults underwent voluntary, spontaneous, and reflex blinking recordings using the EyeStat device and the SMART motion analysis system (BTS, Milan, Italy). During the blinking recordings, the EMG activity was recorded from the orbicularis oculi muscles using surface electrodes. The blinking data were analyzed through dedicated software and evaluated with repeated-measure analyses of variance. The Pearson's product-moment correlation coefficient served to assess possible associations between the EyeStat device, the SMART motion system, and the EMG data. We found that the EMG data collected during the EyeStat and SMART system recordings did not differ. The blinking data recorded with the EyeStat showed a linear relationship with the results obtained with the SMART system (r ranging from 0.85 to 0.57; p ranging from <0.001 to 0.02). These results demonstrate a high accuracy and reliability of a blinking analysis through this portable device, compared with standard techniques. EyeStat may make it easier to record blinking in research activities and in daily clinical practice, thus allowing large-scale studies in healthy subjects and patients with neurological diseases in an outpatient clinic setting.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据