相关参考文献
注意:仅列出部分参考文献,下载原文获取全部文献信息。High-sensitivity liquid-metal-based contact lens sensor for continuous intraocular pressure monitoring
Hongbin An et al.
JOURNAL OF MICROMECHANICS AND MICROENGINEERING (2021)
All-printed stretchable corneal sensor on soft contact lenses for noninvasive and painless ocular electrodiagnosis
Kyunghun Kim et al.
NATURE COMMUNICATIONS (2021)
A soft and transparent contact lens for the wireless quantitative monitoring of intraocular pressure
Joohee Kim et al.
NATURE BIOMEDICAL ENGINEERING (2021)
Integrated contact lens sensor system based on multifunctional ultrathin MoS2 transistors
Shiqi Guo et al.
MATTER (2021)
Rational Design of Capacitive Pressure Sensors Based on Pyramidal Microstructures for Specialized Monitoring of Biosignals
Sara Rachel Arussy Ruth et al.
ADVANCED FUNCTIONAL MATERIALS (2020)
Intraocular Pressure Monitoring Following Islet Transplantation to the Anterior Chamber of the Eye
Joohee Kim et al.
NANO LETTERS (2020)
Spatiotemporal electrochemical sensing in a smart contact lens
Matthew Donora et al.
SENSORS AND ACTUATORS B-CHEMICAL (2020)
Stimulus-Responsive Contact Lens for IOP Measurement or Temperature-Triggered Drug Release
Se-Hee Lee et al.
TRANSLATIONAL VISION SCIENCE & TECHNOLOGY (2020)
Wireless smart contact lens for diabetic diagnosis and therapy
Do Hee Keum et al.
SCIENCE ADVANCES (2020)
Smart, soft contact lens for wireless immunosensing of cortisol
Minjae Ku et al.
SCIENCE ADVANCES (2020)
Near-Field Communication Powered Hydrogel-Based Smart Contact Lens
Andres Vasquez Quintero et al.
ADVANCED MATERIALS TECHNOLOGIES (2020)
Electronic Contact Lens: A Platform for Wireless Health Monitoring Applications
Mengyao Yuan et al.
ADVANCED INTELLIGENT SYSTEMS (2020)
Biodegradable and flexible arterial-pulse sensor for the wireless monitoring of blood flow
Clementine M. Boutry et al.
NATURE BIOMEDICAL ENGINEERING (2019)
Soft, smart contact lenses with integrations of wireless circuits, glucose sensors, and displays
Jihun Park et al.
SCIENCE ADVANCES (2018)
Diurnal and 24-h Intraocular Pressures in Glaucoma: Monitoring Strategies and Impact on Prognosis and Treatment
Anastasios G. Konstas et al.
ADVANCES IN THERAPY (2018)
Wearable smart sensor systems integrated on soft contact lenses for wireless ocular diagnostics
Joohee Kim et al.
NATURE COMMUNICATIONS (2017)
Stretchable Electronic Platform for Soft and Smart Contact Lens Applications
Andres Vasquez Quintero et al.
ADVANCED MATERIALS TECHNOLOGIES (2017)
Soft wearable contact lens sensor for continuous intraocular pressure monitoring
Guo-Zhen Chen et al.
MEDICAL ENGINEERING & PHYSICS (2014)
Continuous wireless pressure monitoring and mapping with ultra-small passive sensors for health monitoring and critical care
Lisa Y. Chen et al.
NATURE COMMUNICATIONS (2014)
Capacitive contact lens sensor for continuous non-invasive intraocular pressure monitoring
Guo-Zhen Chen et al.
SENSORS AND ACTUATORS A-PHYSICAL (2013)
Definition of glaucoma: clinical and experimental concepts
Robert J. Casson et al.
CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY (2012)
A contact lens with an integrated lactate sensor
N. Thomas et al.
SENSORS AND ACTUATORS B-CHEMICAL (2012)
Risk Factors for Visual Field Progression in Treated Glaucoma
Carlos Gustavo V. De Moraes
ARCHIVES OF OPHTHALMOLOGY (2011)
A contact lens with embedded sensor for monitoring tear glucose level
Huanfen Yao et al.
BIOSENSORS & BIOELECTRONICS (2011)
Wireless contact lens sensor for intraocular pressure monitoring: assessment on enucleated pig eyes
Matteo Leonardi et al.
ACTA OPHTHALMOLOGICA (2009)
Clinical utility of Intraocular pressure monitoring outside of normal office hours in patients with glaucoma
Yaniv Barkana et al.
ARCHIVES OF OPHTHALMOLOGY (2006)
Twenty-four-hour intraocular pressure pattern associated with early glaucomatous changes
JHK Liu et al.
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE (2003)