4.7 Article

Bioelectrical impedance spectroscopy can assist to identify the parathyroid gland during thyroid surgery

期刊

FRONTIERS IN ENDOCRINOLOGY
卷 13, 期 -, 页码 -

出版社

FRONTIERS MEDIA SA
DOI: 10.3389/fendo.2022.963520

关键词

bioelectrical impedance spectroscopy; thyroid; parathyroid gland; lymph node; adipose tissue

资金

  1. China Health Promotion Foundation
  2. Scientific Research Fund of the Department of Science and Technology of Chengdu City
  3. Science and Technology Program of Science & Technology Department of Sichuan Province
  4. [2015-HM01-00376-SF]
  5. [2015JY0190]

向作者/读者索取更多资源

This study aimed to explore the effectiveness of bioelectrical impedance spectroscopy in identifying parathyroid glands during thyroid surgeries. The results showed that bioelectrical impedance spectroscopy can assist in differentiating parathyroid glands from peripheral tissues.
Objective: This study aimed to explore the effectiveness of bioelectrical impedance spectroscopy in the identification of parathyroid glands during thyroid surgeries. Method: All patients who received thyroid surgeries at our department from January 2018 to February 2020 were recruited for this study. The bioelectrical impedance spectroscopy analyzer was applied to analyze on following tissues: thyroid tissues, lymph nodes, adipose tissues, and the tissues suspected to be parathyroid glands. Postoperative pathological reports were obtained as the golden standard to compare with the characteristic parameters obtained from bioelectrical impedance spectroscopy. The receiver operating characteristic curve analysis was used to assess the diagnostic value and the selection of the optimal threshold of these parameters from bioelectrical impedance spectroscopy. Results: A total of 512 patients were enrolled in the study and 1898 specimens were measured by the bioelectrical impedance spectroscopy analyzer. There were significant differences in the parameter of f(c) among parathyroid glands, thyroid tissues, lymph nodes, and adipose tissues (252.2 +/- 45.8 vs 144.7 +/- 26.1, 491.7 +/- 87.4, 602.3 +/- 57.3; P<0.001, P<0.001, P<0.001). The area under the receiver operating characteristic curves was 0.993 (95%CI: 0.989-0.996) for f(c). When the diagnostic criterion of f(c) was set at 188.85 kHz similar to 342.55 kHz, the sensitivity and specificity to identify parathyroid glands from lymph nodes and adipose tissues were both 100%. At this f(c,) the sensitivity and specificity to identify parathyroid glands from thyroid tissues were 91.1% and 99.0%, respectively. Conclusion: In conclusion, bioelectrical impedance spectroscopy could assist to differentiate parathyroid glands from peripheral tissues during thyroid surgeries.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据