4.2 Article

Investigation of polycapillary half lenses for quantitative confocal micro-X-ray fluorescence analysis

期刊

JOURNAL OF SYNCHROTRON RADIATION
卷 29, 期 -, 页码 1376-1384

出版社

INT UNION CRYSTALLOGRAPHY
DOI: 10.1107/S1600577522009699

关键词

polycapillary optics; confocal micro-XRF; X-ray fluorescence; 3D elemental analysis; X-ray optics

资金

  1. Technische Universitat Wien Bibliothek [GIP141000XRF]

向作者/读者索取更多资源

The use of polycapillary optics in confocal micro-X-ray fluorescence analysis enables the non-destructive 3D investigation of the elemental composition of samples. This study investigates the transmission properties of polycapillary half lenses and their importance in quantitative interpretation of CMXRF measurements. The results show good agreement between experimental and theoretical values, as well as analysis of fabrication errors and focal spot size.
The use of polycapillary optics in confocal micro-X-ray fluorescence analysis (CMXRF) enables the destruction-free 3D investigation of the elemental composition of samples. The energy-dependent transmission properties, concerning intensity and spatial beam propagation of three polycapillary half lenses, which are vital for the quantitative interpretation of such CMXRF measurements, are investigated in a monochromatic confocal laboratory setup at the Atominstitut of TU Wien, and a synchrotron setup on the BAMline beamline at the BESSY II Synchrotron, Helmholtz-Zentrum-Berlin. The empirically established results, concerning the intensity of the transmitted beam, are compared with theoretical values calculated with the polycap software package and a newly presented analytical model for the transmission function. The resulting form of the newly modelled energy-dependent transmission function is shown to be in good agreement with Monte Carlo simulated results for the complete energy regime, as well as the empirically established results for the energy regime between 6 keV and 20 keV. An analysis of possible fabrication errors was conducted via pinhole scans showing only minor fabrication errors in two of the investigated polycapillary optics. The energy-dependent focal spot size of the primary polycapillary was investigated in the laboratory via the channel-wise evaluation of knife-edge scans. Experimental results are compared with data given by the manufacturer as well as geometric estimations for the minimal focal spot size. Again, the resulting measurement points show a trend in agreement with geometrically estimated results and manufacturer data.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.2
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据