4.7 Article

Experimental Study of Accuracy of High-Rate GNSS in Context of Structural Health Monitoring

期刊

REMOTE SENSING
卷 14, 期 19, 页码 -

出版社

MDPI
DOI: 10.3390/rs14194989

关键词

high-rate GNSS; structural health monitoring; PPP; PPP-AR; RTK

资金

  1. National Key R&D Program of China [2021YFC3000501]
  2. National Natural Science Foundation of China [42004024, 41877289]
  3. Research Grants Council (RGC) of the Hong Kong Special Administrative Region [PolyU 152164/18E, PolyU 152233/19E]

向作者/读者索取更多资源

GNSS-based technologies are crucial in current structural health monitoring systems. High-rate GNSS systems provide more accurate displacement information, but higher sampling rates result in lower measurement accuracy.
Global Navigation Satellite Systems (GNSS)-based technologies have become an indispensable part of current structural health monitoring (SHM) systems because of the unique capability of the GNSS technologies to provide accurate real-time displacement information. GNSS equipment with a data sampling rate of up to about 20 Hz has been widely used for this purpose. High-rate GNSS systems (typically up to about 100 Hz) offer additional advantages in structural health monitoring as some highly dynamic civil structures, such as some bridges, require high-rate monitoring data to capture the dynamic behaviors. However, the performance of high-rate GNSS positioning in the context of structural health monitoring is not entirely known, as studies on structural monitoring with high-rate GNSS positioning are very limited, especially considering that some of the satellite systems just reached their full constellations very recently. We carried out a series of experiments with the help of a shaking table to assess the SHM performance of a set of 100 Hz GNSS equipment and three commonly used GNSS positioning techniques, PPP (precise point positioning), PPP-AR (precise point positioning with ambiguity resolution), and RTK (real-time kinematic). We found that the standard deviations of the 100 Hz GNSS displacement solutions derived from PPP, PPP-AR, and RTK techniques were 5.5 mm, 3.6 mm, and 0.8 mm, respectively, when the antenna was in quasi-static motion, and about 9.2 mm, 6.2 mm, and 3.5 mm, respectively, when the antenna was in vibration (up to about 0.7 Hz), under typical urban observational conditions in Hong Kong. We also found that the higher a sampling rate is, the lower the accuracy of a measured displacement series is. On average, the 10 Hz and 100 Hz results are 5.5% and 10.3%, respectively, noisier than the 1 Hz results.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据