4.7 Article

Near-digital amplification in paper improves sensitivity and speed in biplexed reactions

期刊

SCIENTIFIC REPORTS
卷 12, 期 1, 页码 -

出版社

NATURE PORTFOLIO
DOI: 10.1038/s41598-022-18937-8

关键词

-

资金

  1. DARPA [DSO/BTO-HR0011-11-2-0007]
  2. Bill & Melinda Gates Foundation
  3. National Science Foundation [DGE- 1762114]
  4. University of Washington College of Engineering Dean's Fellowship
  5. University of Washington Department of Bioengineering

向作者/读者索取更多资源

This study demonstrates how near-digital nucleic acid amplification tests can be implemented in low-cost porous media to approach the low limits of detection of digital assays, capturing many benefits of digital NAATs when performed in a paper membrane.
The simplest point-of-care assays are usually paper and plastic devices that detect proteins or nucleic acids at low cost and minimal user steps, albeit with poor limits of detection. Digital assays improve limits of detection and analyte quantification by splitting a sample across many wells (or droplets), preventing diffusion, and performing analyte amplification and detection in multiple small wells. However, truly digital nucleic acid amplification tests (NAATs) require costly consumable cartridges that are precisely manufactured, aligned, and operated to enable low detection limits. In this study, we demonstrate how to implement near-digital NAATs in low-cost porous media while approaching the low limits of detection of digital assays. The near-digital NAAT was enabled by a paper membrane containing lyophilized amplification reagents that automatically, passively meters and distributes a sample over a wide area. Performing a NAAT in the paper membrane while allowing diffusion captures many of the benefits of digital NAATs if the pad is imaged at a high spatial resolution during amplification. We show that the near-digital NAAT is compatible with a low-cost paper and plastic disposable cartridge coupled to a 2-layer rigid printed circuit board heater (the MD NAAT platform). We also demonstrate compatibility with biplexing and imaging with mobile phones with different camera sensors. We show that the near-digital NAAT increased signal-to-noise ratios by similar to 10x, improved limits of detection from above 10(3) copies of methicillin-resistant Staphylococcus aureus genomic DNA to between 100 and 316 copies in a biplexed reaction containing 10(5) copies of co-amplifying internal amplification control DNA, and reduced time-to-result from 45 min of amplification to 15-20 min for the positive samples.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据