4.6 Article

Non-Precious Metal Alloy Double Crown-Retained Removable Partial Dentures: A Cross-Sectional In Vivo Investigation

相关参考文献

注意:仅列出部分参考文献,下载原文获取全部文献信息。
Article Dentistry, Oral Surgery & Medicine

Double-Crown Prosthesis Retention Using Polyetherketoneketone (PEKK): An In Vitro Study

Kensuke Igarashi et al.

Summary: This study assessed the retentive force of telescopic crowns using polyetherketoneketone (PEKK) high-performance polymer in relation to conventional materials over a long period of time in an in vitro setting. The results showed that the PEKK/PEKK and Au/PEKK groups exhibited a similar transition of retentive force compared to the control group, while the Zr/PEKK and Ti/PEKK groups showed a significant decrease in retentive force over time.

JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY (2023)

Article Dentistry, Oral Surgery & Medicine

In vitro investigations on retention force behavior of conventional and modern double crown systems

Viktor Luft et al.

Summary: Long-term use of different double crown systems resulted in retention force losses, with significant decreases in the ZG and CC ZP groups. No significant differences in pull-off force were observed during artificial aging for the GG, NN, and CC ZN groups. Only the Y-TZP primary crowns of the CC ZP group showed no surface changes in wear analysis.

DENTAL MATERIALS (2021)

Article Dentistry, Oral Surgery & Medicine

Retention forces between primary and secondary CAD/CAM manufactured telescopic crowns: an in vitro comparison of common material combinations

Martin Schimmel et al.

Summary: The study found that the retention forces between primary and secondary telescopic crowns are influenced by the material combination, with significant differences in retention forces and wear resistance observed among different materials. Combinations of milled TI/PEEK and NPA/NPA show potential for further testing in a clinically realistic setup.

CLINICAL ORAL INVESTIGATIONS (2021)

Article Dentistry, Oral Surgery & Medicine

Complications of endodontically treated abutment teeth after restoration with non-precious metal double crowns

Sebastian Hinz et al.

CLINICAL ORAL INVESTIGATIONS (2020)

Article Dentistry, Oral Surgery & Medicine

Clinical performance of non-precious metal double crowns with friction pins in severely reduced dentitions

Sebastian Hinz et al.

CLINICAL ORAL INVESTIGATIONS (2020)

Article Dentistry, Oral Surgery & Medicine

Retention of metallic and non-metallic double-crown-retained mandibular overdentures on implants: An in-vitro study

Aya Elkabbany et al.

JOURNAL OF PROSTHODONTIC RESEARCH (2020)

Review Dentistry, Oral Surgery & Medicine

Patient-Reported Outcomes of Metal and Acrylic Resin Removable Partial Dentures: A Systematic Review and Meta-Analysis

Balqees Almufleh et al.

JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY (2020)

Article Dentistry, Oral Surgery & Medicine

Overdentures borne on less than four abutments with telescopic crowns: 5-year results of a retrospective clinical study

Sven Rinke et al.

CLINICAL ORAL INVESTIGATIONS (2019)

Article Dentistry, Oral Surgery & Medicine

Retention Load of Telescopic Crowns with Different Taper Angles between Cobalt-Chromium and Polyetheretherketone Made with Three Different Manufacturing Processes Examined by Pull-Off Test

Christina Wagner et al.

JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY (2018)

Review Dentistry, Oral Surgery & Medicine

Biological complications of removable dental prostheses in the moderately reduced dentition: a systematic literature review

Ovidiu Moldovan et al.

CLINICAL ORAL INVESTIGATIONS (2018)

Article Dentistry, Oral Surgery & Medicine

Nonprecious Alloy vs Precious Alloy Telescopic Crown-Retained Removable Partial Dentures: Survival and Maintenance Needs

Karina Zierden et al.

INTERNATIONAL JOURNAL OF PROSTHODONTICS (2018)

Article Dentistry, Oral Surgery & Medicine

Retention force of removable partial dentures with different double crowns

Christin Arnold et al.

CLINICAL ORAL INVESTIGATIONS (2018)

Review Dentistry, Oral Surgery & Medicine

Factors Influencing Removable Partial Denture Patient-Reported Outcomes of Quality of Life and Satisfaction: A Systematic Review

Ingeborg J. De Kok et al.

JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY (2017)

Article Dentistry, Oral Surgery & Medicine

Electroplated telescopic retainers with zirconia primary crowns: 3-year results from a randomized clinical trial

Franz Sebastian Schwindling et al.

CLINICAL ORAL INVESTIGATIONS (2017)

Article Dentistry, Oral Surgery & Medicine

Double Crown-Retained Maxillary Overdentures: 5-Year Follow-Up

Eberhard Frisch et al.

CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH (2015)

Article Dentistry, Oral Surgery & Medicine

DOUBLE-CROWN RETAINED REMOVABLE DENTAL PROSTHESES: A RETROSPECTIVE STUDY OF SURVIVAL AND COMPLICATIONS

Franz Sebastian Schwindling et al.

JOURNAL OF PROSTHETIC DENTISTRY (2014)

Article Dentistry, Oral Surgery & Medicine

The Fifth German Oral Health Study (Funfte Deutsche Mundgesundheitsstudie, DMS V) - rationale, design, and methods

Rainer A. Jordan et al.

BMC ORAL HEALTH (2014)

Review Dentistry, Oral Surgery & Medicine

Association of removable partial denture use with oral and systemic health

P. M. Preshaw et al.

JOURNAL OF DENTISTRY (2011)

Article Dentistry, Oral Surgery & Medicine

Long-term analysis of telescopic crown retained removable partial dentures: Survival and need for maintenance

Bernd Woestmann et al.

JOURNAL OF DENTISTRY (2007)