Design of a Novel Trabecular Acetabular Cup and Selective Laser Melting Fabrication

期刊

MATERIALS
卷 15, 期 17, 页码 -

出版社

MDPI
DOI: 10.3390/ma15176142

关键词

acetabular cup; porous structure; gradient porosity; Ti6Al4V alloy; selective laser melting

资金

  1. Hebei Province Technology Innovation Guidance Program [20477706D]
  2. Central Government-Guided Local Science and Technology Development Fund [206Z1806G]
  3. Shijiazhuang City Science and Technology Research and Development Program [201200313A]

向作者/读者索取更多资源

The study explores the use of selective laser melting technology to manufacture porous acetabular cups, aiming to prevent stress shielding and subsequent aseptic loosening of total hip replacements. By designing porous structures with different porosity, the mechanical requirements are met while resembling the natural structure of human bone.
The acetabular cups used in total hip arthroplasty are mostly made of dense metal materials with an elastic moduli much higher than that of human bone. This leads to stress shielding after implantation, which may cause aseptic loosening of the implant. Selective laser melting (SLM) technology allows us to produce tiny and complex porous structures and to reduce the elastic moduli of dense metals, thereby avoiding stress shielding. In the present study, rhombic dodecahedron porous structures with cell sizes of 1 mm, 1.5 mm, and 2 mm were designed. The strut diameter was changed to ensure that the porosity and pore size would meet the bone ingrowth requirements. Then, porous Ti6Al4V alloy specimens were printed using SLM, and compressive tests were carried out. The results showed that the compressive strength and elastic modulus values of the specimens with a cell size of 1.5 mm were in the range of 78.16-242.94 MPa and 1.74-4.17 GPa, respectively, which are in line with the mechanical properties of human cortical bone. Finite element analysis of a total hip joint model was carried out to simulate gait, and the surface of the trabecular acetabular cup was divided into 10 regions according to the stress distribution, with the stress interval in the range of 37.44-219.24 MPa. According to the compression test results, the gradient structure of Ti6Al4V alloy with different porosity was designed for trabecular coating. The gradient porous structure meets the mechanical requirements and is closer to the natural structure of human bone than the uniformly distributed porous structure.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据