Assessing a novel second generation laryngeal mask airway using the 'ADEPT' approach: results from the LMA® Protector™ observational study

期刊

出版社

SPRINGER HEIDELBERG
DOI: 10.1007/s10877-022-00910-5

关键词

Supraglottic airway; Airway management; Oxygenation; Laryngeal mask

向作者/读者索取更多资源

To address the lack of clinical evidence for airway devices on the market, the Difficult Airway Society (UK) developed ADEPT, an approach to standardize device evaluation. They assessed the LMA Protector, a second generation laryngeal mask airway, and found it suitable for clinical use with a insertion failure rate of 9.9%.
To address the problem of lack of clinical evidence for airway devices introduced to the market, the Difficult Airway Society (UK) developed an approach (termed ADEPT; Airway Device Evaluation Project Team) to standardise the model for device evaluation. Under this framework we assessed the LMA Protector, a second generation laryngeal mask airway. A total of 111 sequential adult patients were recruited and the LMA Protector inserted after induction of general anaesthesia. Effective insertion was confirmed by resistance to further distal movement, manual ventilation, and listening for gas leakage at the mouth. The breathing circuit was connected to the airway channel and airway patency confirmed with manual test ventilation at 20 cm H(2)0 (water) pressure for 3 s. Data was collected in relation to the time for placement, intraoperative performance and postoperative performance of the airway device. Additionally, investigators rated the ease of insertion and adequacy of lung ventilation on a 5-point scale. The median (interquartile range [range]) time taken to insertion of the device was 31 (26-40[14-780]) s with the ability to ventilate after device insertion 100 (95% CI 96.7- 100)%. Secondary endpoints included one or more manoeuvres 60.3 (95% CI 50.6-69.5)% cases requiring to assist insertion; a median ease of insertion score of 4 (2-5[3-5]), and a median adequacy of ventilation score of 5 (5-5[4-5]). However, the first time insertion rate failure was 9.9% (95% CI 5.1-17.0%). There were no episodes of patient harm recorded, particularly desaturation. The LMA Protector appears suitable for clinical use, but an accompanying article discusses our reflections on the ADEPT approach to studying airway devices from a strategic perspective.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.2
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据